Abstract

In the COVID-19 pandemic caused by SARS-CoV-2, hospitals are often stretched beyond capacity. There are widespread reports of dwindling supplies of personal protective equipment (PPE), particularly N95-type filtering facepiece respirators (FFRs), which are paramount to protect frontline medical/nursing staff, and to minimize further spread of the virus. We carried out a rapid review to summarize the existing literature on the viability of SARS-CoV-2, the efficacy of key potential disinfection procedures against the virus (specifically ultraviolet light and heat), and the impact of these procedures on FFR performance, material integrity, and/or fit. In light of the recent discovery of SARS-CoV-2 and limited associated research, our review also focused on the closely related SARS-CoV-1. We propose a possible whole-of-PPE disinfection solution for potential reuse that could be rapidly instituted in many health care settings, without significant investments in equipment.

Article activity feed

  1. SciScore for 10.1101/2020.04.02.20051409: (What is this?)

    Please note, not all rigor criteria are appropriate for all manuscripts.

    Table 1: Rigor

    Institutional Review Board Statementnot detected.
    Randomizationnot detected.
    Blindingnot detected.
    Power Analysisnot detected.
    Sex as a biological variablenot detected.

    Table 2: Resources

    No key resources detected.


    Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).


    Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.

    Results from TrialIdentifier: No clinical trial numbers were referenced.


    Results from Barzooka: We did not find any issues relating to the usage of bar graphs.


    Results from JetFighter: We did not find any issues relating to colormaps.


    Results from rtransparent:
    • Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
    • Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
    • No protocol registration statement was detected.

    About SciScore

    SciScore is an automated tool that is designed to assist expert reviewers by finding and presenting formulaic information scattered throughout a paper in a standard, easy to digest format. SciScore checks for the presence and correctness of RRIDs (research resource identifiers), and for rigor criteria such as sex and investigator blinding. For details on the theoretical underpinning of rigor criteria and the tools shown here, including references cited, please follow this link.