Hemodynamic modelling improves population receptive field estimates

This article has been Reviewed by the following groups

Read the full article See related articles

Listed in

Log in to save this article

Abstract

Population receptive field (pRF) modelling is a ubiquitous tool in sensory neuroscience for estimating the functional architecture of the human brain. Most pRF models assume a canonical hemodynamic response function (HRF) to account for neurovascular effects. But how does this assumption affect results in practice? Here, we concurrently fit the HRF within the pRF model. Using simulations, we demonstrate that this algorithm accurately estimated different ground truth HRFs used for synthesizing data. Moreover, concurrent fitting improves the accuracy of pRF estimates, especially for the complex Difference-of-Gaussians model. Next, we reanalyzed empirical datasets with different stimulus paradigms and scanning parameters. Concurrent fitting substantially reduced the proportion of implausibly small pRFs. Importantly, the best-fitting HRF differed substantially from canonical HRFs or from those measured independently. HRFs also peaked earlier in higher than early visual cortex, suggesting response nonlinearities. This variability need not only be hemodynamic but could result from neural factors. Critically, all these differences could produce spurious pRF estimates and alter the interpretation of reported findings.

Article activity feed

  1. Dear Dr. Schwarzkopf,

    Thank you for submitting your preprint to Peer Community in Neuroscience. I recognise the significance and depth of this work. Having considered two expert reviews, I have decided that the current preprint merits a revision.

    The reviewers' major concerns centre on the identifiability problem between HRF and pRF parameters, the stability of parameter estimation, and the risk assessment of overfitting.

    Please find the reviewers' comments attached. They offer detailed technical suggestions and requests for further clarification of your modelling choices. I trust their feedback will provide useful guidance for your revision.

    Best regards,

    Seung-Goo Kim

  2. The manuscript by Schwarzkopf et al. presents a timely and methodologically significant advancement for the population receptive field (pRF) modeling community. By introducing a Concurrent fitting approach to estimate both neural pRF parameters and the hemodynamic response function (HRF) parameters simultaneously, the authors address a long-standing concern regarding the impact of regional neurovascular variability on functional mapping (Handwerker et al., 2004). The study is well-powered, utilizes three independent datasets across different field strengths (1.5T, 3T, 7T), and demonstrates a clear reduction in common pRF artifacts, such as the tiny pRF effect. The software implementation within the SamSrf toolbox (Line 486) will likely be highly beneficial for the field.


    Major Comments


    1- Risk of overfitting and parameter stability:

    The concurrent fitting model adds five free parameters to the standard pRF model (Lines 93-96, Lines 510-514). While the authors demonstrate excellent performance in simulations (Fig. 2), the transition to noisy empirical data requires careful consideration of model complexity. In the simulations, a liberal threshold of R² > 0.05 was used (Lines 112-113).

    --- Concern: In empirical data, especially at lower field strengths (e.g., the 1.5T London dataset), there is a risk that the optimization may overfit the noise by adjusting HRF parameters, leading to unstable estimates.

    --- Constructive Suggestion: To strengthen the validation of improvement in empirical data, I suggest the authors calculate the test-retest reliability of the pRF and HRF parameters across separate scanning runs (e.g., comparing Run 1 vs. Run 2). If concurrent fitting provides a more biologically accurate model, one would expect it to yield more consistent maps than the biased canonical model. Alternatively, the authors could show how the HRF parameters vary as a function of SNR to ensure that the earlier peak findings are not driven by noise in higher visual areas.


    2- Regional HRF Latencies and Physiological Interpretation:

    The finding that HRFs in higher-level regions (LO and MT) peak approximately 1–2 seconds earlier than in early visual cortex (V1–V3) (Fig. 1I, Fig. 5A-C, Lines 224-229) is highly intriguing but, as the authors acknowledge, somewhat counterintuitive (Lines 420-427). Standard models of neural hierarchy suggest longer neural latencies in higher areas.

    --- Concern: While the authors mention response nonlinearities (Line 22), it is unclear if this is a purely vascular effect or an artifact of the periodic stimulus design interacting with compressive spatial summation (Kay et al., 2013).

    --- Constructive Suggestion: The authors could clarify this by comparing their results with previous independent HRF mapping studies that used event-related or breath-holding designs (e.g., Aguirre et al., 1998; Handwerker et al., 2004). If the earlier peak is specific to the pRF mapping stimuli, it might suggest a temporal nonlinearity (non-linear summation over time) rather than a faster vascular response per se. Discussing these differences in the context of the London dataset (where MT and V1 peaked similarly, Line 248) would add valuable nuance.


    3- Comparison with Existing HRF Optimization Procedures:

    The authors describe a coarse-to-fine approach for fitting the HRF parameters (Lines 496-504). Previous pRF implementations, such as those in vistasoft (specifically rmHrfFit.m), already included a stage for optimizing HRF parameters after an initial coarse grid search for spatial pRF parameters. Could the authors clarify what is fundamentally different or improved in their concurrent fitting approach within SamSrf compared to this existing iterative coarse-to-fine HRF tuning procedure in vistasoft/mrVista? For instance, does the concurrent fit explore the combined pRF-HRF parameter space more effectively than an alternating/iterative approach?


    4- Stimulus Design Sensitivity:

    The authors find that concurrent fitting has a substantial impact on bar stimuli (Lines 313-333) but a minimal effect on combined wedge-and-ring stimuli (Lines 335-358).

    --- Concern: This is a critical finding for researchers deciding whether to re-analyze legacy datasets. However, the reason for this difference is only briefly touched upon.

    --- Constructive Suggestion: It would be very helpful if the authors could elaborate on the mathematical or signal-processing reasons for this dissociation. For instance, does the higher duty cycle or the specific spatial frequency content of the wedge-and-ring design make the model less sensitive to temporal delays? Providing a clearer guideline for when researchers must use concurrent fitting would increase the paper's impact.


    Minor Comments


    1- Abbreviation Consistency: Please ensure all technical abbreviations, such as "DoG" (Difference-of-Gaussian) are explicitly defined at their first mention.

    2- Initialization: The authors initialize the search using the SPM canonical HRF (Lines 511-512). A brief comment on whether the final solution is robust to different starting points (e.g., a fast vs. slow HRF initialization) would reassure readers about the optimization's global convergence.

    3- Figure 1I Precision: In Figure 1I (Page 3), the dashed black line (canonical HRF) is very close to some of the empirical curves. It would be helpful to include the numerical values for the peak latencies (e.g., in a table or as text in the legend) to make the comparison more precise for the reader.

     

    Questionnaire


    Title and abstract

    * Does the title clearly reflect the content of the article? [X] Yes

    * Does the abstract present the main findings of the study? [X] Yes


    Introduction

    * Are the research questions/hypotheses/predictions clearly presented? [X] Yes

    * Does the introduction build on relevant research in the field? [X] Yes (Excellent coverage of HRF confounds in pRF modeling, e.g., Line 58).


    Materials and methods

    * Are the methods and analyses sufficiently detailed to allow replication by other researchers? [X] Yes (The use of an open-source toolbox like SamSrf is a major plus).

    * If applicable (for empirical studies), are sample sizes are clearly justified? [X] Yes (The use of three independent datasets provides strong justification).

    * Are the methods and statistical analyses appropriate and well described? [X] Yes


    Results

    * In the case of negative results, is there a statistical power analysis? [N/A]

    * Are the results described and interpreted correctly? [X] Yes (The distinction between simulated and empirical results is clear).


    Discussion

    * Have the authors appropriately emphasized the strengths and limitations of their study? [X] Yes (Lines 420-475 provide a balanced view).

    * Are the conclusions adequately supported by the results? [X] Yes

     


    References

    • Aguirre, G. K., Zarahn, E., & D'Esposito, M. (1998). The variability of human, BOLD hemodynamic responses. NeuroImage, 8(1), 36-69.
    • Handwerker, J. K., Ollinger, J. M., & D'Esposito, M. (2004). Variation of BOLD hemodynamic responses across subjects and brain regions and their effects on statistical analyses. NeuroImage, 21(4), 1639-1651.
    • Kay, K. N., Winawer, J., Mezer, A., & Wandell, B. A. (2013). Compressive spatial summation in human visual cortex. Journal of Neurophysiology, 110(2), 481-494.
    • Lerma-Usabiaga, G., Benson, N., Winawer, J., & Wandell, B. A. (2020). A validation framework for neuroimaging software: the case of population receptive fields. PLoS Computational Biology, 16(6), e1007924.

  3. ​​In this manuscript, the authors introduce a concurrent HRF–pRF fitting framework and examine how HRF assumptions influence pRF estimates through comprehensive simulations and empirical analyses. I think that this is an interesting and potentially impactful contribution, and the technical implementation is clearly substantial. However, there are several conceptual and interpretational issues that I think need to be addressed before the work is ready for publication.

    In particular, I found that some of the claims regarding HRF recovery and “improvement” in pRF estimates are somewhat overstated. More importantly, the manuscript does not fully resolve or explicitly acknowledge the identifiability problem between HRF and pRF parameters. In addition, there are several places where model-dependent effects are interpreted in physiological terms, which it would be better if they could be handled more cautiously. Clarifying these points, along with some methodological choices, and strengthening the discussion of limitations, would significantly improve the paper! 

    I therefore recommend major revision. Detailed comments are provided below, organized by section.

    The Introduction is generally well-written and provides a solid conceptual foundation on pRF modeling and the role of the HRF as both a critical modeling assumption and a potential confound. However, a few points could be improved:

    1.     The manuscript presents what seems like somewhat contradictory statements regarding the impact of HRF assumptions on pRF estimates (Lines 54–59) without adequately reconciling them. This inconsistency should be explicitly addressed. It would help to clarify under what conditions HRF variability matters and to explain why earlier studies may have underestimated these effects. 

    2.     The introduction lacks a clear concluding paragraph that explicitly states the specific research gap, the specific question addressed here, what novel contributions are. As a result, the section feels more descriptive rather than a focused setup for the study. 

    3.     The discussion of HRF variability is largely limited to differences across brain regions. However, the literature also highlights substantial variability in HRF characteristics across individuals, as well as potential modulation by task context and cognitive state, which could be relevant here. Briefly acknowledging this would provide a more comprehensive and balanced framing of the problem. 

    4.     Some statements would benefit from improved precision, clarity, and stronger support from the literature:

    a.     The claim that pRF modeling estimates neuronal populations “ directly” is a bit misleading, since this is still a model-based inference from BOLD signals. 

    b.     The statement that “pRF modeling has become the most popular method…” would benefit from either a reference or more cautious wording. 

    c.     Several sentences are overly long and quite dense and could be simplified for readability (e.g., the discussion of HRF nonlinearity and stimulus duration dependence)

     

    In the Results section, the authors present a very comprehensive simulation framework (including multiple HRFs, pRF models, stimuli, and field strengths). The inclusion of empirical datasets is a clear strength. That said, there are several issues about interpretation and framing that should be addressed: 

    1.     The opening of the Results section introduces the study objective (“ we sought to investigate variability in HRFs”), which would be more appropriately placed in the final paragraph of the Introduction. More importantly, I am not sure this is the most accurate description of what is being done! The analyses primarily assess the impact of allowing HRF parameters to vary on pRF estimates, rather than directly characterizing HRF variability. This distinction should be clarified to better align the stated objectives with the actual methodological approach performed.

    2.     The statement that the “Concurrent fit identifies true HRF” appears overstated. Since the simulations use HRFs generated from the same parametric family as the fitting model, this is essentially a model-matched scenario. In that case, good recovery is expected and does not necessarily generalize to more empirical (mismatched) conditions or realistic model settings. It would be better to frame this as recovery under idealized conditions. Including additional simulations introducing model mismatch or non-parametric HRFs would also strengthen the claims. 

    3.     Despite an extensive simulation framework, they do not fully address the fundamental identifiability issue between HRF and pRF parameters. It is still unclear whether the Concurrent fit yields unique solutions or whether there are trade-offs between parameters that could lead to multiple plausible fits. Some discussion or analysis of this would strengthen the paper.

    4.     The goodness-of-fit threshold (R2 >0.05) for selecting voxels included in HRF averaging was extremely low, which could introduce bias by including poorly constrained estimates. It would be helpful to justify this choice and/or show that the results are robust to more restrictive thresholds!

    5.     Throughout the Results, the Concurrent fit is described as “improving” pRF estimates. For stimulations, this is fair because there is ground truth, but for empirical data this is harder to justify. Therefore, it might be more accurate to say that pRF estimates change systematically depending on  HRF assumptions.

    6.     Several interpretative statements regarding implications of short TR designs or HRF differences across datasets, are more appropriate for the Discussion section and should be relocated.

    Overall, the Discussion is strong and well-structured, and well-aligned with the Results. It appropriately summarizing the main findings and situating them in the literature. The points about key factors such as nonlinearity, TR, and stimulus design limitations, are particularly useful. However, there are a few conceptual issues that I think need to be addressed more explicitly:

    1.     While the study appears to primarily support model dependence of pRF estimates on HRF parameters, in several places, the manuscript interprets differences in estimated HRFs across regions and datasets as evidence of physiological variability. However, since these HRFs are estimated jointly with pRF parameters, and given the potential identifiability issue, it seems equally plausible that these differences are model dependent. This distinction should be made more clearly.

    2.     The identifiability issue is not really discussed in depth. Given that HRF shape and pRF parameters can trade off against each other, it would be important to acknowledge that the HRF+pRF model may not have a unique solution.

    3.     The interpretation that the smaller pRF estimates under the canonical HRF may reflect “implausible” or “artifactual results” requires stronger justification. An alternative possibility is that the Concurrent fit shifts the parameterization of the model without necessarily bringing it closer to ground truth ( at least in empirical data). It would be good to acknowledge this.

    4.     The limitations section could be strengthened. In particular, it would be helping to explicitly acknowledge: the use of a specific HRF model, the lack of ground truth in empirical data, identifiability, and uncertainty/variability in parameter estimates.

    5.     Finally, a few statements feel somewhat strong or speculative (e.g., “could represent the perfect compromise”). These should be softened to better reflect the evidence more cautiously.

    Overall, I think this is a strong and worthwhile contribution, and I appreciate the scope of the simulations and analyses. Addressing the points above, particularly around identifiability, interpretation of HRF variability, and the strength of the claims, would substantially improve the clarity and rigor of the manuscript.

  4. Dear Dr Schwarzkopf,

    Thank you for submitting the revised version of your manuscript. The reviewers and I appreciate your efforts in revising the manuscript and believe that most of the points raised have been well addressed.

    However, a few minor points remain that could improve the manuscript's readability. Therefore, I believe that the manuscript would benefit from one further round of minor revisions.

    Please find the reviewers' comments attached.

    Best regards,

    Seung-Goo Kim

  5. Response to the authors: Hemodynamic modelling improves pRF estimates


    I would like to thank the authors for their thoughtful revision and their detailed response. I think the manuscript has improved considerably. Regarding my own comments, the Introduction now mentions HRF variability across individuals and brain regions, and the aim of the study is described more accurately and has been moved to the end of the Introduction, where it fits better. The claims about HRF recovery are more measured, and the added limitation on the double-gamma HRF family is helpful. I also appreciate the new analysis showing that the simulation results hold at stricter R² thresholds. The interpretation of the regional HRF differences is now more cautious, and describing them as a property of the fMRI response within a given mapping paradigm, rather than as purely neurovascular differences, makes good sense to me.

    The changes made in response to the other reviewer have also strengthened the paper. The cross-validation of the Auckland data is reassuring with respect to overfitting and shows that the HRF estimates are reproducible across independent runs. The comparison with earlier studies of HRF variability and the peak latencies now reported for Figure 1 give useful context, and the recommendations on when to use concurrent HRF fitting will be valuable for readers. I was also pleased to see the reanalysis of the spatial-frequency adaptation data, which partly answers my earlier question about task-related changes in the HRF.

     

    Most of my concerns have been addressed. I have a few remaining suggestions, which I think can mostly be handled with changes to the text.

     

    1.     Identifiability. I appreciate the detailed discussion of identifiability in the response letter. In the manuscript itself, however, the issue is only touched on briefly (L358–362), and I think readers would benefit if some of that discussion made it into the paper. A short paragraph in the Discussion would be enough. It could mention that the temporal HRF parameters and pRF size may trade off to some extent, since, as the authors note in the Introduction (L68–70), the HRF acts as a spatiotemporal kernel when the stimulus moves across the visual field. It could then point out that the simulations argue against a serious problem here, at least for the Gaussian model at TR = 1 s, because both the HRF and pRF size were recovered well. It may also be worth noting that the two cross-validation folds share the same stimulus sequence, so the cross-validation speaks mainly to overfitting to noise rather than to whether the parameter solutions are unique. If the authors are comfortable with it, a brief mention of the grid-search spot tests described in the response, with the caveat they give there, would also be helpful.

    2.     Model-matched recovery. A short sentence in the Results noting that the ground-truth HRFs come from the same double-gamma family as the fitted model would help readers interpret the recovery results. I accept the authors' point that good recovery is not guaranteed in this setting, but I still think this context is useful.

    3.     Wording. I may have missed it, but the sentence “This design could represent the perfect compromise…” (L409–410) seems to be unchanged in the revised version. Something like “may offer a good compromise” might fit the evidence better. In the same spirit, the authors might consider toning down “it is evidently inappropriate to assume…” (L543–545) and “It would be trivial to extend…” (L588).

    4.     pRF size differences. L370–372 says that concurrent fitting consistently yielded larger pRFs with sweeping bar stimuli. This seems to hold for early visual cortex, but if I read Figure 6B correctly, the Canonical fit gives larger median pRF sizes in several higher-level areas of the Auckland dataset (e.g., MT, V3A, IPS0, VO). Figure 7A shows a similar pattern in V3A. It may be more accurate to restrict this statement to early visual areas, or to mention the exception.

    5.     Introduction. I still feel the Introduction would read more smoothly with one or two sentences explaining how the earlier reports of a negligible HRF effect (Dumoulin and Wandell, 2008; van Dijk et al., 2016) fit with the later findings of Lerma-Usabiaga et al. (2020), for example, under which conditions a misspecified HRF matters most. The final paragraph could also state the research gap a little more explicitly. The sentence in the original version (“To our knowledge, no study has systematically investigated…”) did this nicely, and the authors may wish to bring it back.

    6.     Methods and reporting. The Altan et al. (2025b) dataset is a nice addition, but it is not yet described in the Methods. A short subsection like those for the other datasets (number of participants, scanner, TR, stimulus, inclusion threshold) would be useful. The number of datasets is also given as three at L218 and four at L349. For the cross-validation, it would help to state how vertices were selected and to give a brief quantitative summary in the main text, for instance the median difference in cR² per region. Finally, where HRFs are described as similar (V1 and MT in the London data, L247–248) or virtually identical (the two adaptation conditions, L300–301 and L552), slightly more cautious wording may be safer, since a non-significant difference does not by itself show equivalence. An equivalence or Bayesian test would be one option, but softer wording would be fine too.

    7.     Minor points. A few small things I noticed: the Figure 1 caption implies a V1–MT difference of about 1.5 s, whereas L509 mentions around 2 s. The Results section now begins with “Henceforth, we refer to this as the Concurrent fit” (L96), which seems to have lost its referent when the preceding sentence was moved to the Introduction. There are also a few typos (e.g., “conversative” at L145, “These left the possibility” at L291, the double negative at L339, the repeated “therefore” at L357, and “have modelling” at L572). Lastly, the authors might want to change the Discussion heading at L474 to “HRF estimates differ…” so that it matches the corresponding Results heading.

     

    Recommendation: Minor revision. This is a careful and useful study, and once these minor points have been addressed, I would be happy to recommend it for publication.

     

    Questionnaire answers:

    Title and abstract

    Does the title clearly reflect the content of the article? [X] Yes
    Does the abstract present the main findings of the study? [X] Yes


    Introduction

    Are the research questions/hypotheses/predictions clearly presented? [X] No (minor). The aim is now stated at the end of the Introduction, which is an improvement. The research gap could be stated a little more explicitly, as it was in the original version.
    Does the introduction build on relevant research in the field? [X] Yes


    Materials and methods

    Are the methods and analyses sufficiently detailed to allow replication by other researchers? [X] No (minor). Most analyses are well described, and it is great that the data and code are openly available. The Altan et al. (2025b) dataset still needs a short description in the Methods, and the cross-validation procedure (in particular vertex selection) could be described in a bit more detail.
    If applicable (for empirical studies), are sample sizes clearly justified? [X] No. No formal justification is given, but I do not see this as a concern. This is a methods study based on existing datasets, and the selection of the HCP subset is explained.
    Are the methods and statistical analyses appropriate and well described? [X] No (minor). The analyses themselves seem appropriate to me. It would help, though, to report the cross-validation results quantitatively in the main text (e.g., the median change in cR² per region), and to give some measure of the reduced inter-individual variability in the adaptation reanalysis, which is currently described only as “numerically” lower.


    Results

    In the case of negative results, is there a statistical power analysis (or an adequate Bayesian analysis or equivalence testing)? [X] No. In two places a non-significant difference is described as similarity: the V1 and MT HRF latencies in the London dataset (p = 0.44) and the “virtually identical” HRFs in the two adaptation conditions. Slightly softer wording, or an equivalence or Bayesian test, would address this.
    Are the results described and interpreted correctly? [X] No (minor). The results are mostly described correctly. The statement that concurrent fitting “consistently yielded larger pRFs” seems to hold for early visual cortex but not for several higher-level areas (Figure 6B, Auckland dataset; Figure 7A, V3A). There is also a small inconsistency in the V1–MT latency difference (about 1.5 s in the Figure 1 caption versus around 2 s in the text).


    Discussion

    Have the authors appropriately emphasized the strengths and limitations of their study/theory/methods/argument? [X] No (minor). Several limitations are now acknowledged, including the double-gamma HRF family, the lack of ground truth in empirical data, and the choice of initial HRF. The possible trade-off between HRF and pRF parameters, however, is mentioned only briefly, and I think a short paragraph on it would be helpful.
    Are the conclusions adequately supported by the results (without overstating the implications of the findings)? [X] No (minor). The main conclusions are well supported. A few phrases are somewhat stronger than the evidence (e.g., “could represent the perfect compromise”, “evidently inappropriate”, “It would be trivial to extend”), and toning these down would help.
     

  6. Population receptive field (pRF) modelling (Dumoulin & Wandell, 2008) predicts the fMRI response of each voxel by projecting a moving stimulus onto a model receptive field and convolving the result with a hemodynamic response function (HRF). Most studies assume one canonical HRF for the whole brain, although HRFs are known to vary between individuals and brain regions (Handwerker et al., 2004). Since the stimulus moves through the visual field over time, the HRF acts as a spatiotemporal kernel; that is, an error in the assumed response timing can be absorbed by spatial parameters such as pRF size.

    In the current preprint, Schwarzkopf and colleagues (2026) estimate the five parameters of a double-gamma HRF together with the pRF parameters at each vertex of the cortical surface (the "Concurrent fit"). The novelty is twofold. First, unlike earlier procedures that refit a single HRF for the whole brain after an initial pRF fit (e.g., Harvey & Dumoulin, 2011), the HRF is optimised simultaneously with the pRF and is allowed to vary across the cortex. Second, ground-truth simulations show what a misspecified HRF does to pRF estimates: it shrinks the estimated pRF size and, with a difference-of-Gaussians model, produces pronounced inhibitory surrounds for pRFs that in fact have none. Fitting the HRF largely removed both biases (at a repetition time of 1 s).

    In four existing datasets (1.5- to 7-T fMRI, including the Human Connectome Project retinotopy data; Benson et al., 2018), the fitted HRFs differed from canonical HRFs and from independently measured impulse responses, as well as between datasets and visual regions (with sweeping bars, the response peaked 1–2 s earlier in V3A and MT than in V1–V3). To the authors' knowledge, this is the first description of how HRF shape varies across regions within pRF mapping paradigms. Since these latency differences are much larger than neuronal latency differences along the visual hierarchy, the authors propose that the fitted HRF describes the fMRI response to a given paradigm rather than a purely neurovascular property.

    Two reviewers evaluated the manuscript over two rounds, and the revisions strengthened it considerably. In the first round, the reviewers asked whether the five additional HRF parameters lead to overfitting, how the regional latency differences should be interpreted, how the Concurrent fit differs from existing iterative procedures, and why its benefit depends on the stimulus design. The authors responded with (i) a split-half cross-validation, in which the Concurrent fit predicted left-out runs better than the canonical HRF in nearly all participants and regions, with HRF estimates reproducible across folds; (ii) simulations with stricter inclusion thresholds; and (iii) a reanalysis of their own spatial-frequency adaptation study (Altan et al., 2025), in which the original effect on pRF size held. They also added practical guidelines on when to use concurrent HRF fitting, for instance as a robustness check when comparing conditions or groups of participants. In the second round, the authors discussed the identifiability of HRF and pRF parameters in more depth and moderated several claims (e.g., restricting the larger pRF sizes under the Concurrent fit to early visual cortex).

    I recommend this preprint because it addresses an assumption that nearly every pRF study makes and shows, with ground truth, when this assumption matters. The finding that a mismatched HRF alone can create inhibitory surrounds is an important caution for center-surround and normalisation models, which are increasingly used to compare groups of participants or drug conditions (e.g., Aqil et al., 2021). The method is openly available in the SamSrf toolbox (version 10), and the authors are clear about its limits: the HRF is recovered poorly at repetition times of 2 s or longer, and, without ground truth, a trade-off between HRF timing and pRF size cannot be fully excluded. Beyond retinotopy, the same point may apply to other forward models in which stimulus timing is confounded with the hemodynamic kernel, such as tonotopic mapping or encoding models of naturalistic stimuli.

    References

    Ecem Altan, Catherine A. Morgan, Steven C. Dakin, D. Samuel Schwarzkopf (2025) Spatial frequency adaptation modulates population receptive field sizes. eLife, 13, RP100734 https://doi.org/10.7554/eLife.100734

    Marco Aqil, Tomas Knapen, Serge O. Dumoulin (2021) Divisive normalization unifies disparate response signatures throughout the human visual hierarchy. Proceedings of the National Academy of Sciences of the United States of America, 118(46), e2108713118 https://doi.org/10.1073/pnas.2108713118

    Noah C. Benson, Keith W. Jamison, Michael J. Arcaro, An T. Vu, Matthew F. Glasser, Timothy S. Coalson, David C. Van Essen, Essa Yacoub, Kamil Ugurbil, Jonathan Winawer, Kendrick Kay (2018) The Human Connectome Project 7 Tesla retinotopy dataset: Description and population receptive field analysis. Journal of Vision, 18(13), 23 https://doi.org/10.1167/18.13.23

    Serge O. Dumoulin, Brian A. Wandell (2008) Population receptive field estimates in human visual cortex. NeuroImage, 39(2), 647–660 https://doi.org/10.1016/j.neuroimage.2007.09.034

    Daniel A. Handwerker, John M. Ollinger, Mark D'Esposito (2004) Variation of BOLD hemodynamic responses across subjects and brain regions and their effects on statistical analyses. NeuroImage, 21(4), 1639–1651 https://doi.org/10.1016/j.neuroimage.2003.11.029

    Ben M. Harvey, Serge O. Dumoulin (2011) The relationship between cortical magnification factor and population receptive field size in human visual cortex: Constancies in cortical architecture. Journal of Neuroscience, 31(38), 13604–13612 https://doi.org/10.1523/JNEUROSCI.2572-11.2011

    D. Samuel Schwarzkopf, Ecem Altan, Steven C. Dakin, Catherine A. Morgan (2026) Hemodynamic modelling improves population receptive field estimates. bioRxiv, ver.3 peer-reviewed and recommended by PCI Neuroscience https://doi.org/10.1101/2025.11.17.688931​