Low-Temperature Gamma Irradiation Dosimetry for the Development of Streptococcus agalactiae Group B Vaccine Candidate Against Bovine Subclinical Mastitis

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Gamma irradiation is a promising method for microbial inactivation in vaccine production, especially for heat-sensitive microorganisms, as it can preserve antigenic structures while ensuring pathogen safety. Because heat-sensitive microorganisms are prone to damage at room or elevated temperatures, low-temperature irradiation is essential to maintain protein integrity. A major challenge in this process is accurate dose measurement, as routine dosimeter calibration is typically performed at room-temperature, which can lead to inaccuracies under freezing conditions. In this study, polymethyl methacrylate (PMMA) dosimeters were calibrated under low-temperature environments maintained by dry ice (solid state of carbon dioxide; -700C to -300C). The influence of medium density on the absorbed dose was examined by comparing dry ice with wood pellets as a density-equivalent dummy. Dose-response data obtained at room-temperature using wood pellets were interpolated with the low-temperature data (using dry ice) to correct for temperature-dependent variations in dosimeter sensitivity. Results showed a polynomial relationship between dose and absorbance (R2=0.9996), with sensitivity decreasing above 10 kGy and saturation occurring near 50 kGy. At low-temperatures, dosimeter responses deviated from room-temperature calibration due to effects of dry ice and altered density. Correction was achieved by interpolating absorbance responses between dry ice (low-temperature) and wood pellets (room-temperature density-equivalent medium), and irradiator dose setting must be approximately 17.70% higher than the target dose to compensate for attenuation and achieve the desired absorbed dose. Dose uniformity ratios (DUR) across target doses (2–25 kGy) remained <1.1, confirming the homogeneity of irradiation and met the requirements of ISO 11137. This method provides a reliable dosimetric framework for low-temperature gamma irradiation, supporting its application in the development of vaccines against heat-sensitive microorganisms such as Group B Streptococcus agalactiae.

Article activity feed