Superiority of 68Ga-PSMA-11 PET/CT Over mpMRI for Lateral Diagnosis of Intra-Glandular Prostate Cancer Lesions: Avoiding Fluke Targeting
Listed in
This article is not in any list yet, why not save it to one of your lists.Abstract
Objective The aim of this study was to compare the diagnostic accuracy of 68 Ga-PSMA-11 PET/CT and multiparametric MRI (mpMRI) in detecting unilateral and bilateral intra-glandular prostate cancer lesions. Methods A retrospective analysis was conducted on 73 prostate cancer patients diagnosed via biopsy, all of whom underwent both 68 Ga-PSMA-11 PET/CT and mpMRI prior to surgery. Two independent readers, blinded to each other’s results and to pathology findings, evaluated the imaging modalities to make a lateral diagnosis of suspected prostate lesions. Histopathological findings from a 12-core transrectal ultrasound-guided biopsy and radical prostatectomy served as reference standards. The accuracy of both imaging modalities in determining unilateral and bilateral intra-glandular prostate cancer was assessed through receiver operating characteristic curve analysis. Additionally, factors influencing diagnostic discordance between the two modalities were evaluated. Results A total of 73 patients were included in the final analysis, comprising 34 with unilateral lesions and 39 with bilateral lesions. Among these, 35 patients underwent radical prostatectomy, revealing 22 cases of bilateral lesions and 13 cases of unilateral lesions (Kappa = 0.76 ( P < 0.001). The lateral diagnostic accuracy of 68 Ga-PSMA-11 PET/CT, based on pathological results from biopsy or prostatectomy, was 80.82% (59/73) and 82.86% (29/35), respectively. These values were significantly higher than those of mpMRI, which demonstrated an accuracy of 54.79% (40/73, P <0.001) and 40% (14/35, P <0.001), respectively. Concordance between 68 Ga-PSMA-11 PET/CT and mpMRI for the lateral diagnosis was poor (kappa = 0.015, P < 0.05). When both imaging modalities provided consistent lateralization results (39/73), concordance with pathological findings reached 87.18% (34/39). However, concordance with pathological results was significantly higher for 68 Ga-PSMA-11 PET/CT (76.47%, 26/34) compared to mpMRI (20.59%, 7/34). Further analysis revealed that an SUVmax > 3.95 for 68 Ga-PSMA-11 PET/CT and a PI-RADS score ≥ 4 for mpMRI were independent factors influencing lateral diagnostic concordance. Conclusion The 68 Ga-PSMA-11 PET/CT demonstrated significantly higher accuracy than mpMRI in the lateral diagnosis of intra-glandular prostate cancer. There was considerable inconsistency in the diagnostic outcomes between 68 Ga-PSMA-11 PET/CT and mpMRI, and in cases of discordance, 68 Ga-PSMA-11 PET/CT was notably more accurate. SUVmax ≥ 3.95 and PI-RADS score ≥ 4 were critical factors influencing the correct lateral diagnosis when the results from 68 Ga-PSMA-11 PET/CT and mpMRI were inconsistent.