Comparative assessment of multiple COVID-19 serological technologies supports continued evaluation of point-of-care lateral flow assays in hospital and community healthcare settings
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
No abstract available
Article activity feed
-
-
SciScore for 10.1101/2020.06.02.20120345: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Antibodies Sentences Resources Lateral Flow Immunoassays (LFIA): We tested seven point-of-care colloidal-gold-based LFIAs detecting IgG and IgM antibodies against SARS-CoV-2. colloidal-gold-based LFIAs detecting IgGsuggested: NoneSARS-CoV-2suggested: NoneExperimental Models: Cell Lines Sentences Resources This protein was expressed in 500 mL HEK-293F cells (Invitrogen) at a density of 1.5 million cells/mL. HEK-293Fsuggested: RRID:CVCL_6642)Software and Algorithms Sentences Resources Statistic… SciScore for 10.1101/2020.06.02.20120345: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Antibodies Sentences Resources Lateral Flow Immunoassays (LFIA): We tested seven point-of-care colloidal-gold-based LFIAs detecting IgG and IgM antibodies against SARS-CoV-2. colloidal-gold-based LFIAs detecting IgGsuggested: NoneSARS-CoV-2suggested: NoneExperimental Models: Cell Lines Sentences Resources This protein was expressed in 500 mL HEK-293F cells (Invitrogen) at a density of 1.5 million cells/mL. HEK-293Fsuggested: RRID:CVCL_6642)Software and Algorithms Sentences Resources Statistical Analysis: Expected binomial exact 95% confidence intervals were calculated on Prism 8.0 using Wilson/Brown statistical analysis. Prismsuggested: (PRISM, RRID:SCR_005375)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-