The properties of hot household hygroscopic materials and their potential use for non-medical facemask decontamination
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
The widespread use of facemasks throughout the population is recommended by the WHO to reduce transmission of the SARS-CoV-2 virus. As some regions of the world are facing mask shortages, reuse may be necessary. However, used masks are considered as a potential hazard that may spread and transmit disease if they are not decontaminated correctly and systematically before reuse. As a result, the inappropriate decontamination practices that are commonly witnessed in the general public are challenging management of the epidemic at a large scale. To achieve public acceptance and implementation, decontamination procedures need to be low-cost and simple. We propose the use of hot hygroscopic materials to decontaminate non-medical facemasks in household settings. We report on the inactivation of a viral load on a facial mask exposed to hot hygroscopic materials for 15 minutes. As opposed to recent academic studies whereby decontamination is achieved by maintaining heat and humidity above a given value, a more flexible procedure is proposed here using a slow decaying pattern, which is both effective and easier to implement, suggesting straightforward public deployment and hence reliable implementation by the population.
Article activity feed
-
-
SciScore for 10.1101/2020.07.16.20155481: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources For each inactivation study, 15 000 VERO E6 cells were seeded in 24 well plates for 24 hours to reach 80% confluence. VERO E6suggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We …SciScore for 10.1101/2020.07.16.20155481: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources For each inactivation study, 15 000 VERO E6 cells were seeded in 24 well plates for 24 hours to reach 80% confluence. VERO E6suggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- No funding statement was detected.
- No protocol registration statement was detected.
-
