Aerosol decontamination and spatial separation using a free-space LED-based UV-C light curtain
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Background
The SARS-CoV-2 pandemic demonstrated the vulnerability of our societies to aerosol transmitted pathogens. With no less than 260mio known cases and > 5mio deaths, SARS-CoV-2 is a global catastrophe leading to human and economic losses unprecedented in recent history. Thus, effective methods to limit the spread of aerosol transmitted pathogens are needed. Universal masking and curfew laws are effective but no permanent solution.
Methods
A mass producible LED light source emitting homogeneous parallel UV-C light was used as a “light-barrier” to block the spread of infectious aerosols. In an aerosol test channel, Gram-negative and Gram-positive bacteria as well as coronavirus were nebulized and inactivation rates were determined.
Findings
With air speeds of 0.1 m s -1 an exposure time of 1 s in the UV-C light is obtained. Reduction in CFU for E. coli was >3log10 and for S. aureus ∼2.8log10. Plug-forming-units of the murine coronavirus (Mouse Hepatitis Virus, MHV) were reduced by about 3log10.
Interpretation
The concept of a UV-C light barrier to ward off infectious aerosols if feasible and possible with a light element as described here. Coupled with sensor based activation/deactivation, such a technology could greatly reduce the transmission rates of aerosol transmitted pathogens while not disturbing natural human behaviour. This is an interesting technology allowing a “new normal” in societies after/with SARS-CoV-2.
Article activity feed
-
SciScore for 10.1101/2021.12.16.21267937: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter:…
SciScore for 10.1101/2021.12.16.21267937: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: Please consider improving the rainbow (“jet”) colormap(s) used on pages 6 and 7. At least one figure is not accessible to readers with colorblindness and/or is not true to the data, i.e. not perceptually uniform.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-