Nanoviricide’s platform technology based NV-CoV-2 polymer increases the half-life of Remdesivir in vivo
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
So far, there are seven coronaviruses identified that infect humans and only 4 of them belong to the beta family of coronavirus (HCoV-HKU1, SARS-CoV-2, MERS-CoV and SARS-CoV). SARS family are known to cause severe respiratory disease in humans. In fact, SARS-CoV-2 infection caused a pandemic COVID-19 disease with high morbidity and mortality. Remdesivir (RDV) is the only antiviral drug so far approved for COVID-19 therapy by the FDA. However, the efficacy of RDV in vivo is limited due to its low stability in presence of plasma. This is the report of analysis of the non-clinical pharmacology study of NV-CoV-2 (Polymer) and NV-CoV-2-R (Polymer encapsulated Remdesivir) in both infected and uninfected rats with SARS-CoV-2.
Detection and quantification of NV-CoV-2-R in plasma samples was done by MS-HPLC chromatography analyses of precipitated plasma samples from rat subjects.
NV-CoV-2-R show RDV peak in MS-HPLC chromatography, whereas only NV-CoV-2 does not show any RDV-Peak, as expected.
NV-CoV-2 polymer encapsulation protects RDV in vivo from plasma-mediated catabolism.
Body weight measurements of the normal (uninfected) rats after administration of the test materials (NV-CoV-2, and NV-CoV-2-R) show no toxic effects on them.
Our platform technology based NV-387-encapsulated-RDV (NV-CoV-2-R) drug has a dual effect on coronaviruses. First, NV-CoV-2 itself as an antiviral regimen. Secondly, RDV is protected from plasma-mediated degradation in transit, rendering altogether the safest and an efficient regimen against COVID-19.
Article activity feed
-
SciScore for 10.1101/2021.11.17.468980: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Experimental Models: Organisms/Strains Sentences Resources Test Articles: In vivo Treatment: Thirty-six Sprague Dawley rats (Taconic Biosciences, USA) (three/ each sex in control and in treatment groups) were administered with NV-CoV-2 or NV-CoV-2-R, once per day for 5 days (0, 1, 3, 5, and 7) over a 7-day time period. Sprague Dawleysuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit …SciScore for 10.1101/2021.11.17.468980: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Experimental Models: Organisms/Strains Sentences Resources Test Articles: In vivo Treatment: Thirty-six Sprague Dawley rats (Taconic Biosciences, USA) (three/ each sex in control and in treatment groups) were administered with NV-CoV-2 or NV-CoV-2-R, once per day for 5 days (0, 1, 3, 5, and 7) over a 7-day time period. Sprague Dawleysuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-