Improving human coronavirus OC43 (HCoV-OC43) research comparability in studies using HCoV-OC43 as a surrogate for SARS-CoV-2
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2021.07.14.452401: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources Cell lines: HRT-18/HTC-8 (ATCC CCL-224) cells were maintained in RPMI-1640 (ATCC formulation) (Gibco, Fisher Scientific), 2% heat-inactivated (HI) fetal bovine serum (FBS) (Gibco, Fisher Scientific) and 2mM L-glutamine (Corning, Fisher Scientific). HRT-18/HTC-8suggested: NonePlaque Assays: MRC-5 cells or Vero E6 cells were seeded in 12 or 24-well plates and incubated at 37°C, 5% CO2 until 80-90% confluent. MRC-5suggested: NoneVero E6suggested: RRID:CVCL_XD71)Results …
SciScore for 10.1101/2021.07.14.452401: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources Cell lines: HRT-18/HTC-8 (ATCC CCL-224) cells were maintained in RPMI-1640 (ATCC formulation) (Gibco, Fisher Scientific), 2% heat-inactivated (HI) fetal bovine serum (FBS) (Gibco, Fisher Scientific) and 2mM L-glutamine (Corning, Fisher Scientific). HRT-18/HTC-8suggested: NonePlaque Assays: MRC-5 cells or Vero E6 cells were seeded in 12 or 24-well plates and incubated at 37°C, 5% CO2 until 80-90% confluent. MRC-5suggested: NoneVero E6suggested: RRID:CVCL_XD71)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- No funding statement was detected.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-