In Vitro Efficacy of “Essential Iodine Drops” Against Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2)
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Background
Aerosolization of respiratory droplets is considered the main route of coronavirus disease 2019 (COVID-19). Therefore, reducing the viral load of Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2) shed via respiratory droplets is potentially an ideal strategy to prevent the spread of the pandemic. The in vitro virucidal activity of intranasal Povidone-Iodine (PVP-I) has been demonstrated recently to reduce SARS-CoV-2 viral titres. This study evaluated the virucidal activity of the aqueous solution of Iodine-V (a clathrate complex formed by elemental iodine and fulvic acid) as in Essential Iodine Drops (EID) with 200 μg elemental iodine/ml content against SARS-CoV-2 to ascertain whether it is a better alternative to PVP-I.
Methods
SARS-CoV-2 (USAWA1/2020 strain) virus stock was prepared by infecting Vero 76 cells (ATCC CRL-1587) until cytopathic effect (CPE). The virucidal activity of EID against SARS-CoV-2 was tested in three dilutions (1:1; 2:1 and 3:1) in triplicates by incubating at room temperature (22 ± 2°C) for either 60 or 90 seconds. The surviving viruses from each sample were quantified by a standard end-point dilution assay.
Results
EID (200 μg iodine/ml) after exposure for 60 and 90 seconds was compared to controls. In both cases, the viral titre was reduced by 99% (LRV 2.0). The 1:1 dilution of EID with virus reduced SARS-CoV-2 virus from 31,623 cell culture infectious dose 50% (CCCID 50 ) to 316 CCID 50 within 90 seconds.
Conclusion
Substantial reductions in LRV by Iodine-V in EID confirmed the activity of EID against SARS-CoV-2 in vitro, demonstrating that Iodine-V in EID is effective at inactivating the virus in vitro and therefore suggesting its potential application intranasally to reduce SARS-CoV-2 transmission from known or suspected COVID-19 patients.
Article activity feed
-
SciScore for 10.1101/2020.11.07.370726: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources The virus stock was prepared by infecting Vero 76 cells (ATCC CRL-1587) until cytopathic effect (CPE) was visible at two days postinoculation. Vero 76suggested: NoneSoftware and Algorithms Sentences Resources The Vero 76 cells were cultured in Minimal Essential Medium (MEM) (Quality Biological), supplemented with 2% (v/v Quality Biologicalsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. …
SciScore for 10.1101/2020.11.07.370726: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources The virus stock was prepared by infecting Vero 76 cells (ATCC CRL-1587) until cytopathic effect (CPE) was visible at two days postinoculation. Vero 76suggested: NoneSoftware and Algorithms Sentences Resources The Vero 76 cells were cultured in Minimal Essential Medium (MEM) (Quality Biological), supplemented with 2% (v/v Quality Biologicalsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-