Luminore CopperTouch Surface Coating Effectively Inactivates SARS-CoV-2, Ebola Virus, and Marburg Virus In Vitro
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
We investigated the ability of Luminore CopperTouch copper and copper-nickel surfaces to inactivate filoviruses and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The copper and copper-nickel surfaces inactivated 99.9% of Ebola and Marburg viruses after 30 min, and the copper surfaces inactivated 99% of SARS-CoV-2 in 2 h.
Article activity feed
-
-
SciScore for 10.1101/2020.07.05.20146043: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources Vero E6 cells were grown to 70%−80% confluence in 6- or 12-well plates. Vero E6suggested: RRID:CVCL_XD71)The drops were collected with 90 µl of fresh dilution medium and titrated on Vero cells using a TCID50 assay. Verosuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An …SciScore for 10.1101/2020.07.05.20146043: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources Vero E6 cells were grown to 70%−80% confluence in 6- or 12-well plates. Vero E6suggested: RRID:CVCL_XD71)The drops were collected with 90 µl of fresh dilution medium and titrated on Vero cells using a TCID50 assay. Verosuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We found bar graphs of continuous data. We recommend replacing bar graphs with more informative graphics, as many different datasets can lead to the same bar graph. The actual data may suggest different conclusions from the summary statistics. For more information, please see Weissgerber et al (2015).
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-