COVID-19 PCR test performance on samples stored at ambient temperature
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2020.06.15.153882: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Sample Collection, Transportation, and Storage: This study was approved by the Umraniye Teaching and Research Hospital ethical committee Nasopharyngeal/oropharyngeal swabs were collected by trained personnel and transferred to GLAB-Corona 7 in Viral Transport Media (VTM, Innomed VTM001). Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the …SciScore for 10.1101/2020.06.15.153882: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Sample Collection, Transportation, and Storage: This study was approved by the Umraniye Teaching and Research Hospital ethical committee Nasopharyngeal/oropharyngeal swabs were collected by trained personnel and transferred to GLAB-Corona 7 in Viral Transport Media (VTM, Innomed VTM001). Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:The limitation of our study is the considered range of temperatures, between 20°C and 24°C. Temperatures higher than 24°C may be common in some tropical research and/or storage settings so the time period that samples remain positive may be variable. Also, the limited number of samples can be counted as another limitation of our study.
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- No conflict of interest statement was detected. If there are no conflicts, we encourage authors to explicit state so.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-