In vivo evaluation of the virucidal efficacy of chlorhexidine and povidone-iodine mouthwashes against salivary SARS-CoV-2. A randomized-controlled clinical trial
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2021.03.07.21252302: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Ethical approval: Ethical clear of this research was delivered from the Lebanese University Institutional Review Board (#CUER 13-2020).
Consent: All participants were informed about the study and gave their consent.Randomization Sampling: Participants were randomly divided into the three groups. Blinding Trial design: This study was a parallel group, quadruple blind-randomized-placebo-controlled clinical trial with an add on laboratory based study. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources RNA was extracted from the clinical samples on Kingfisher flex purification system … SciScore for 10.1101/2021.03.07.21252302: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Ethical approval: Ethical clear of this research was delivered from the Lebanese University Institutional Review Board (#CUER 13-2020).
Consent: All participants were informed about the study and gave their consent.Randomization Sampling: Participants were randomly divided into the three groups. Blinding Trial design: This study was a parallel group, quadruple blind-randomized-placebo-controlled clinical trial with an add on laboratory based study. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources RNA was extracted from the clinical samples on Kingfisher flex purification system Thermo Fisher using MagMAX(tm) Viral/Pathogen Nucleic Acid Isolation Kit (thermos fisher). Thermo Fisher using MagMAX(tmsuggested: None31 Statistical Analysis: The analysis of data was carried out using GraphPad Prism version 5 for Windows (GraphPad Software, La Jolla California USA, www.graphpad.com).
GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)GraphPadsuggested: (GraphPad Prism, RRID:SCR_002798)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-