Evaluating the Incremental Value of AI-Derived ECG Features Beyond Automated ECG Reports and Clinical Data for 30-Day Mortality: A MIMIC-IV Cohort Study

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Automated electrocardiogram (ECG) reports and clinical records already carry prognostic information, so the relevant question is what artificial intelligence (AI)-derived ECG waveform features add beyond these existing sources, and whether models with similar overall discrimination would prioritize the same patients for review. In linked Medical Information Mart for Intensive Care IV (MIMIC-IV) data, we compared 15 prespecified ECG morphology measurements with features from a previously trained deep-learning model for 30-day all-cause mortality in the same 25,430 held-out patients (924 deaths). Both feature sets fed identical prediction models developed and evaluated with the same procedures; paired 95% confidence intervals quantify each difference, basic clinical history — age, recorded sex, and prior-diagnosis indicators — was held constant where indicated, and analyses are labelled prespecified or post hoc. The AI-feature model ranked 30-day mortality risk better than the morphology model (area under the receiver operating characteristic curve 0.812 versus 0.737; +0.075, 95% CI +0.059 to +0.091), and the advantage persisted with basic clinical history (+0.053, +0.039 to +0.067). In post hoc comparisons with basic clinical history held constant, replacing the expanded automated report associated with the index ECG with AI features changed discrimination little (+0.0037, −0.0053 to +0.0126), and adding AI features to the report-based model yielded +0.0075 (−0.0005 to +0.0151); both intervals include zero. At a hypothetical fixed 5% review capacity, the prespecified ECG-only comparison identified 236 versus 163 subsequent deaths (AI features versus morphology measurements), and with basic clinical history the corresponding post hoc comparison identified 262 versus 221. In a separate post hoc comparison using separately refitted models, the AI-feature and expanded-report review lists captured 262 versus 261 subsequent deaths (paired difference +1, 95% CI −25 to +22), yet shared only 654 of their 1,272 flagged patients: similar totals, different patient lists. One-year transport to a Brazilian cohort absent from the model’s earlier training retained the advantage over morphology measurements. These retrospective risk rankings measure prioritization, not prevented mortality: the advantage over richer routine reports was small and uncertain, and equal-capacity lists flagged different patients, so comparator strength and patient selection merit evaluation alongside discrimination before clinical use.

Article activity feed