PharmaAgent: a real-world evaluation of high- and low-autonomy agentic systems for inpatient vancomycin dosing

Read the full article

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Vancomycin has a narrow therapeutic window requiring individualized dosing and repeated monitoring, a process many health systems delegate from physicians to pharmacists. We silently deployed PharmaAgent, LLM-based vancomycin dosing agentic systems, at Stanford Hospital for two months and compared high- and low-autonomy configurations, each with and without institutional guidelines. Across 403 dosing events in 316 patients, mean absolute percentage error against the treating pharmacist’s order was 21.8% with high autonomy versus 37.8% with low autonomy, and recommendations were within 25% of the order in 73.4% versus 50.9% of events (P < 0.001); a second pharmacist was within 25% of the treating pharmacist’s order in 90.2% of events. Pharmacist review of 196 out-of-tolerance recommendations found a safety concern in 65.8%, more often with low autonomy (odds ratio 2.37). A higher-autonomy agent that self-debugged its steps proved more robust than stricter engineering, but neither configuration is ready to dose patients without pharmacist oversight.

Article activity feed