Thoracoabdominal pressure transmission during prone and supine cardiopulmonary resuscitation in fresh-frozen human cadavers
Listed in
This article is not in any list yet, why not save it to one of your lists.Abstract
Aim
Prone cardiopulmonary resuscitation (CPR) may be necessary when turning a prone patient supine would delay chest compressions. Although prone compressions can generate arterial pressures comparable with or greater than supine CPR, the pathway of pressure transmission is uncertain. We examined synchronized intrathoracic, intra-abdominal, and central arterial pressures in both supine and prone positions.
Methods
Two thawed fresh-frozen adult cadavers underwent three, 2-minute mechanical CPR trials per position in a counterbalanced crossover sequence. Solid-state catheters recorded pleural, peritoneal, and central arterial pressures simultaneously. Trial-level outcomes included peak pressure, mean pressure, pressure-time area, and the mean peritoneal-to-pleural pressure gradient. Exploratory fixed-effects models included position, cadaver, and their interaction.
Results
Prone CPR increased peak intrathoracic pressure by 7.04 mmHg, peak intra-abdominal pressure by 21.69 mmHg, and peak arterial pressure by 15.40 mmHg. Mean intra-abdominal and arterial pressures increased by 16.22 and 9.90 mmHg, respectively. The mean peritoneal-to-pleural gradient reversed direction from −8.46 mmHg supine to 4.85 mmHg prone. Intrathoracic pressure-time area increased 3.4-fold, from 1.62 to 5.46 mmHg·s, and arterial pressure-time area increased 2.2-fold, from 2.96 to 6.42 mmHg·s.
Conclusion
Compared to supine, prone mechanical CPR generated higher arterial pressures and altered the pressure relationship across the thoracoabdominal boundary in both cadavers. Higher abdominal pressure coincided with a larger intrathoracic pressure-time area, a pattern compatible with reduced caudal pressure dissipation. Because diaphragm motion was not measured, this proposed mechanism remains inferential.