Evaluations of retrospective frequency and phase correction methods for single-voxel MR spectroscopy at 7T

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Subject motion and gradient heating-induced frequency and phase offsets result in spectral misalignment during single-voxel MR spectroscopy (SVS) acquisitions. Several methods have been presented to align the spectra, but their performance on a 7T system is unclear. This study aimed to evaluate the practical importance of four retrospective correction methods, namely creatine fitting, residual water, spectral registration, and cross-correlation. SVS data were collected from 127 participants (88/39 female/male, 39±15 years) using a semi-localization by adiabatic selective refocusing sequence at 7T. Changes in the spectral linewidth, signal-to-noise ratio (SNR), similarity (mean similarity matrix (SI mean )), and metabolite quantification (concentration, relative Cramer-Rao lower bounds (rCRLB)) after correction were evaluated. A Wilcoxon signed rank test was used to evaluate these changes. The p -values were adjusted using the false discovery rate ( q <0.05) for multiple comparisons. For significant changes, the effect size was further calculated using the Rosenthal formula. The results demonstrated that all correction methods resulted in a significant decrease in the spectral linewidth and significant increases in the spectral SNR and SI mean . The mean changes by using the four methods were 0.76-0.99 Hz for the spectral linewidth change (effect sizes:0.73-0.86), 5.79-6.95 for the SNR change (effect size:0.60-0.72), and 0.03-0.03 for the SI mean change (effect size:0.87-0.87). The correction also significantly increased the estimates of the metabolite concentrations of PCr, Gln, Glu, GPC, Ins, NAA, Scyllo, and Tau (effect size:0.25-0.57), and significantly decreased the rCRLBs (effect size:0.26-0.42) of Scyllo, Tau, and Gly. These results indicate that each method provides practical benefits in improving the spectral linewidth, SNR, and similarity by showing a strong to very strong effect of the improvements (effect size>0.60). The correction only showed a weak to moderate effect of the changes in the metabolite quantification (effect size<0.60), suggesting that whether the correction results in more reliable metabolite quantification requires further validation.

Article activity feed