Validation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosis

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Objectives

To validate two computational fluid dynamics (CFD) models derived from computed tomography angiography (CTA) for estimating trans-stenotic pressure gradients, using invasive intra-arterial pressure measurements as the reference standard in patients with renal artery stenosis (RAS).

Background

We assessed whether non-invasive assessment of the pressure gradient using CFD could be a reliable alternative to intra-arterial measurements for identifying hemodynamically significant RAS.

Methods

We performed intra-arterial measurements at rest and during dopamine-induced hyperemia to assess the trans-stenotic pressure gradient in 28 patients with RAS. A pre-intervention CTA scan was used to simulate the pressure gradient with a CFD model using a strategy based on Murray’s law (CFD-Mu) and cortical volume (CFD-C). The agreement between the simulated and measured pressure gradients was assessed using intraclass correlation coefficients (ICC), Bland-Altman analysis and diagnostic agreement on the presence of a hemodynamically significant stenosis.

Results

In 20 patients, successful measurements and simulations were obtained. The ICC between measured pressure gradient and the CFD pressure gradient was 0.78 and 0.94 during baseline and 0.86 and 0.72 during hyperemia, for CFD-Mu and CFD-C, respectively. The sensitivity of CFD-Mu and CFD-C was 70% for both models at rest and 100% compared to the hyperemic measurements, whereas the specificity was 90% and 70% at rest and 79% and 72% during hyperemia, respectively.

Conclusions

The results support the use of individualized CFD simulations for hemodynamic assessment of RAS using CTA as input. The CFD models demonstrated high accuracy for the identification of a hemodynamically significant stenosis.