Long-term mitigation of the foreign-body response with dexamethasone-eluting cochlear implants in mice

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

The inflammatory foreign body response that follows cochlear implantation produces intracochlear fibrosis, neo-ossification, and elevated electrode impedances that can compromise implant performance. Dexamethasone-eluting cochlear implants reduce this response, but the durability of their anti-inflammatory effect over long implantation intervals has not been established. Using a murine model of chronic cochlear implantation in CX3CR1+/eGFP Thy1+/eYFP dual-reporter mice, we compared dexamethasone-eluting and standard mouse cochlear implants at 224 and 336 days post-implantation. Density of CX3CR1+ macrophages, MHCII+CX3CR1+ antigen-presenting macrophages, α-SMA+ fibrosis, and neo-ossification were quantified in the scala tympani, Rosenthal canal, and lateral wall of the basal turn. Standard implants produced persistent macrophage and antigen-presenting macrophage infiltration, accompanied by an α-SMA+ fibrotic response and neo-ossification. Dexamethasone-eluting implants suppressed macrophage infiltration in all three regions out to 336 days and reduced fibrosis at 224 days. In the subset of cochleae with electrode array translocation, dexamethasone-eluting implants attenuated macrophage infiltration and confined the fibrotic and osseous response to the site of translocation, whereas standard implants produced a widespread response. A reduction in immune cell density was also observed in the contralateral, unimplanted cochleae of animals implanted with dexamethasone-eluting implants, suggesting a wider component to the drug’s effect. Dexamethasone-eluting cochlear implants therefore provide sustained, long-term suppression of the cochlear foreign body response in mice, supporting their continued translation toward clinical application. This effect was associated with continued low-level dexamethasone elution out to 336 days post-implantation; further work is needed to assess the durability of this effect at the conclusion of drug elution.

Highlights

  • Dexamethasone-eluting implants suppress cochlear foreign body response out to 336 days

  • Low-level dexamethasone elution persisted through 336 days post-implantation

  • Dexamethasone-eluting implants reduce inflammatory response to array translocation

Article activity feed