Deep learning-based identification and quantification of rare circulating hybrid cells in orthotopic pancreatic cancer models

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Significance

Rare-cell identification in fluorescence microscopy remains challenging because targets are sparse and background varies between specimens. Combining specimen-specific fluorescence enrichment with image classification may enable efficient and more specific automated detection of rare cells.

Aim

We developed a two-stage framework to identify and quantify candidate rare circulating hybrid neoplastic cells (CHCs, ECAD+/CD45+) in peripheral blood mononuclear cell (PBMC) preparations from tumor-bearing and tumor-naïve mice.

Approach

PBMCs from 28 mice were imaged by multichannel fluorescence microscopy. Matched unstained samples established animal-specific ECAD and CD45 background distributions for candidate cell enrichment. Blinded multi-annotator consensus labels were used to train a convolutional neural network (CNN) from DAPI, ECAD, and CD45 image crops. Generalization was evaluated by leave-one-animal-out validation across 10 random initializations. Final classification used a 10-model ensemble, and rare-cell burden was compared between groups using negative-binomial regression with total segmented-cell count as an exposure.

Results

Of the 1,065,512 segmented cells, enrichment retained 10,176 candidates (0.96%), reducing the search space by >99%. Four of five evaluable tumor-bearing animals showed reproducible held-out discrimination, with median quantified area under the receiver operator characteristic curve (AUROCs) of 0.918–0.951; one animal was a reproducible outlier (median AUROC, 0.338). Ensemble deployment identified 157.94 positive-consensus cells per 50,000 segmented cells in tumor-bearing animals versus 49.55 in controls. The estimated rare-cell rate was 3.15-fold higher in tumor-bearing animals (95% CI, 0.91–10.99; two-sided p=0.071; prespecified one-sided p=0.036).

Conclusions

Specimen-specific fluorescence enrichment combined with supervised image classification reduced the cellular search space and enabled automated quantification of a rare CHC (ECAD+/CD45+) phenotypes. Cross-animal validation also identified specimen-specific generalization failure, highlighting the importance of biological-specimen-level validation.

Article activity feed