Synchrotron phase contrast micro-CT of prostate tissue

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Formalin-fixed prostate tissue samples were imaged by propagation-based synchrotron phase contrast micro computed tomography ( µ CT) with a 3D spatial resolution of ca. 3 µ m. Post- µ CT, samples were prepared for histology with sections close to coplanar with the transverse µ CT image planes. Haematoxylin and eosin stained sections were examined by an expert prostate histopathologist and compared qualitatively with corresponding µ CT-visible microstructure features. There is potential for µ CT to provide complimentary information to conventional histology and light microscopy without the need for preparation of stained thin sections. For the imaging conditions and spatial resolution of our study, µ CT may provide tissue architectural features similar to those used in Gleason grading, albeit without clear subcellular microstructure detail. At the spatial resolution of our study µ CT may provide novel 3D microstructure information for validation of diffusion weighted magnetic resonance imaging (MRI) methods. As an example, we demonstrate a qualitative correlation between µ CT-derived stromal fibre orientation and preferential water diffusion direction measured by diffusion tensor MRI microscopy of the same sample.