Abstract

Prior analyses have demonstrated an inverse association between transcatheter aortic valve replacement (TAVR) procedural volume and short-term outcomes. However, less is known regarding the relationship between procedural volume and 1-year outcomes in the contemporary TAVR era.

Objectives

To evaluate the association between annual hospital and operator TAVR procedural volumes and 1-year clinical outcomes in a contemporary national cohort.

Methods

Clinical records from the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapies (TVT) Registry for patients undergoing commercial TAVR between January 2020 and December 2022 were linked to Centers for Medicare & Medicaid Services administrative claims. Annualized hospital and operator TAVR volumes were modeled continuously and categorized into tertiles. Primary outcomes included 1-year all-cause mortality, stroke, the composite of mortality or stroke, and all-cause readmissions. Hierarchical risk-adjusted models accounting for patient clustering within sites were used to evaluate associations between procedural volume and outcomes.

Results

Among 215,335 patients undergoing TAVR at 788 hospitals by 3,444 operators between 2020 and 2022, median annual hospital and operator volumes were 74 (IQR: 43-115) and 16 (IQR: 10-32), respectively. Volume was then categorized into tertiles (low, medium and high). Compared with high-volume hospitals (≥102/year), low-volume hospitals (≤52/year) had higher adjusted rates of 1-year all-cause mortality (Odds Ratio (OR): 1.10 [95% CI: 1.05-1.16]), stroke (OR: 1.10 [95% CI: 1.01-1.19]), mortality or stroke (OR: 1.10 [95% CI: 1.05-1.15]), and all-cause readmissions (OR: 1.05 [95% CI: 1.00-1.09]). Compared with high-volume operators (≥25/year), low-volume operators (≤11/year) had higher adjusted rates of stroke (OR: 1.16 [95% CI: 1.05-1.28]) and mortality or stroke (OR: 1.09 [95% CI: 1.03-1.15]) but not other endpoints.

Conclusions

In a large, contemporary national TAVR registry, lower annual hospital (≤ 52/year) and operator (≤ 11/year) procedural volumes were independently associated with worse 1-year clinical outcomes. These findings suggest that procedural experience continues to influence outcomes despite maturation of contemporary TAVR practice.