SURPASS-HF: Safety and Utility of Remote Pulmonary Artery Sensor Shared-management in Heart Failure

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Background

Insulin-dependent diabetics self-titrate therapy to self-obtained glucose values as standard of care, yet heart failure (HF) patients with implanted pulmonary artery (PA) pressure sensors never see their own readings; clinicians interpret and execute every dose change - a model that does not scale to a ∼200-patient HF panel. To our knowledge, SURPASS-HF is the first prospective feasibility study applying the insulin-titration paradigm to PA-pressure-guided HF care: patients executing a prescribed loop-diuretic sliding scale, supported by ARTHUR, a domain-trained large language model, with clinician confirmation of every adjustment.

Methods

Non-randomized, prospective, single-arm, single-center 90-day feasibility study (January 14-April 14, 2026; 60.1 patient-months). Twenty-one adults with implanted PA sensors enrolled (intention-to-treat, ITT); 19 completed full follow-up (per-protocol, PP). Regimens and individual PA diastolic (PAD) targets were explicitly prescribed; when daily pressures met published serial-reading thresholds, the software prepared the pre-determined adjustment, the clinician confirmed it, and the patient executed it. ARTHUR reinforced dose ceilings, prompted surveillance labs, and escalated edge cases for review. Pre-specified outcomes: adverse events, escalations, time in optimal PA range (TIR-PAP, +/-5 mmHg of goal), reading adherence, provider overrides, and paired delta_PAD (first vs last 7-day windows). Confidence intervals are descriptive; the study was not powered for significance.

Results

Mean age was 69+/-11 years, 52% women, mean baseline PAD 14.8 mmHg. No pre-specified safety event (KDIGO >or=1 AKI, hyperkalemia, hyponatremia, symptomatic hypotension) was detected (0/8 post-adjustment draws in 5/21 patients; exact 95% CI 0-37%); laboratory ascertainment was sparse, so a meaningful harm rate cannot be excluded. Seventeen of 19 PP patients (89%) required no protocol-triggered escalation; 4 escalations occurred in 2 patients. TIR-PAP was 88.4% (ITT)/91.3% (PP); reading adherence 92.1%; 53 provider alerts (0.88/patient-month) all resolved (median 24 h) with no overrides. delta_PAD was -0.89 mmHg (ITT; 95% CI -2.60 to +0.82) in a cohort already at goal at baseline. Two non-cardiac hospitalizations occurred.

Conclusions

LLM-mediated, clinician-confirmed patient execution of a published deterministic PA-pressure-guided diuretic algorithm was feasible over 90 days, with high time-in-range and adherence and no detected safety events. Findings from this prospective, single arm, non-randomized, small cohort are descriptive. The study was not designed or powered to demonstrate evidence of a treatment effect; a randomized, well powered prospective comparison study against provider-led PA-pressure management is the next ideal step.