Image-based deep learning for emergency electrocardiogram classification
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
This article is not in any list yet, why not save it to one of your lists.Abstract
Automated electrocardiogram analysis has advanced largely through digital waveforms, yet many emergency-care workflows rely on ECGs available only as printed tracings, scanned reports, PDFs or mobile photographs. We developed an image-based deep learning system for emergency ECG classification and evaluated it in InCor-EMG, an expert-adjudicated dataset of 18,519 emergency ECGs spanning 12 ECG categories, with labels from 19 cardiologists. On the held-out test set, the final ConvNeXt ensemble achieved a macro F1-score of 0.807 (95% CI, 0.788–0.825), compared with 0.820 (95% CI, 0.805–0.832) for annotating cardiologists, and higher F1-scores than Mortara Veritas ™ in most evaluated categories. Performance was associated more strongly with inter-reader agreement than with training sample size and remained informative across scanned and photographed ECGs, with supportive performance in model-enriched temporal and heterogeneous public-image evaluations. These findings support ECG-image classification when digital waveforms are unavailable.