GLLaucoMed: A Secure LLM-Powered Agentic Workflow for Automated Medication Extraction from Free-Text Glaucoma Clinical Notes

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Purpose

To evaluate the efficacy of large language models (LLMs) in extracting medication-related information from glaucoma clinical notes in the electronic health record (EHR).

Design

Cross-sectional.

Subjects

1,250 subjects in the Bascom Palmer Ophthalmic Repository.

Methods

Extracted clinical notes from glaucoma-related encounters between 2014 and 2024 were labeled by two glaucoma specialists with a third serving as an adjudicator. Graders were asked to label current topical medications (CTM), proposed changes to topical medications (ΔTM), current oral medications (COM), and proposed changes to oral medications (ΔOM) in a structured fashion. The dataset was split into development (10%), validation (10%), and test (80%) sets stratified by clinician. Development and validation sets were used to engineer and refine prompts, and the held-out test set was used for model assessment. Five LLMs (Claude Opus 4.6, DeepSeek-V3.2, GPT 5.2, Grok 4.1, and Qwen3.6-35B-A3B) were accessed via Microsoft Azure AI Foundry within a HIPAA-compliant environment. Inter-grader agreement was assessed with Gwet AC1. LLM performance was initially assessed in a binary fashion with F1 scores, and the degree of text match among positive cases was evaluated using exact match accuracy and Jaccard Index (JI).

Main Outcome Measures

F1 score, exact match accuracy, JI.

Results

Gwet AC1 for intergrader agreement was 0.799, 0.888, 0.985, and 0.988 for CTM, ΔTM, COM, and ΔOM, respectively. F1 scores for CTM were 0.985, 0.971, 0.978, 0.968, and 0.970 for Claude, Deepseek, GPT, Grok, and Qwen, respectively; for ΔTM: 0.905, 0.826, 0.897, 0.842, 0.855, respectively; for COM: 0.923, 0.887, 0.899, 0.906, 0.894, respectively; for ΔOM: 0.958, 0.815, 0.937, 0.835, 0.940, respectively. Among positive cases, range of exact match accuracies for CTM (N=1354) was 0.730-0.882 and range of JIs was 0.809-0.918. For ΔTM (N=404), exact match accuracy range was 0.619-0.780 and JI range was 0.668-0.827. For COM (N=47), exact match accuracy range was 0.766-0.872 and JI range was 0.765-0.870. For ΔOM (N=25), exact match accuracy range was 0.583-0.920 and JI range was 0.583-0.922.

Conclusions

The GLLaucoMed pipeline demonstrated high performance in extracting and standardizing medication data from unstructured clinical notes, including both current medications and proposed changes. Claude and GPT exhibited the strongest performance.

Article activity feed