The Multimodal Anonymizer: a fully local multi-agent AI system for medical data deidentification

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Background

Safe reuse of multimodal hospital data for AI development is limited by the absence of reliable, context-aware deidentification across multimodal data and longitudinal patient data. Existing approaches are largely modality-specific and can indiscriminately remove clinically important information.

Methods

We developed the Multimodal Anonymizer, a modular, locally deployable multi-agent framework integrating multimodal large language models, task-specific neural networks and rule-based transformations. We evaluated 16 orchestrator model configurations on a benchmark built from publicly available data and hospital data from our institution. The benchmark dataset included data from different origins: 250 MIMIC-IV patients with synthetically injected personally identifiable information (PII) supplemented with head CT, face images, handwriting, audio, German clinical-text datasets and local data. Primary outcomes were deidentification sensitivity and preservation of clinically important content; secondary analyses examined model characteristics, reproducibility, and performance against leading market and open-source solutions.

Results

The best local configuration—the orchestrator being Qwen3-VL-235B-A22B-Thinking—achieved near-complete deidentification across all datasets, with per-patient sensitivity of 98.80% (95%-CI 97.20; 100), and per-PII sensitivity of 99.82% (95%-CI 99.76; 99.88). Critical clinical preservation was 99.60% (95%-CI 98.80; 100) per-patient, and clinical preservation was 99.61% (95%-CI 99.51; 99.71) per-file. All modalities achieved at least 98.30% sensitivity (lower bound 95%-CI). On our local data, the system achieved a deidentification sensitivity of 100% per-patient and per-PII; and a critical clinical preservation of 100% per-patient as well as a clinical preservation of 99.97% (95%-CI 99.91; 100) per-file. When comparing orchestrators, the leading local models were similar to proprietary models (GPT-5.2) in deidentification sensitivity while showing higher deidentification specificity. The Multimodal Anonymizer outperformed previous tools on most modalities.

Conclusion

Near-complete, utility-preserving deidentification of multimodal clinical data is achievable with a unified, locally deployable multi-agent system, enabling safer large-scale reuse of hospital data for research and AI development.

Graphical Abstract

Highlights

  • Framework for deidentification of multimodal clinical data.

  • Multimodal deidentification with preservation of clinically relevant content.

  • On-premises plug-and-play deployment for local data processing.

  • Evaluation of 16 model configurations and comparison with existing tools.

  • Assessment on external, multilingual and site-specific datasets.

Short Description

The Multimodal Anonymizer is a fully local, multi-agent system that prepares multimodal clinical records for privacy-preserving reuse by coordinating multimodal large language model reasoning, specialist neural networks, rule-based transformations, and iterative verification. Across benchmarks spanning text, tables, PDFs, imaging, metadata, filenames, audio, and handwriting, its best configuration using a local open-source multimodal large language model achieved 98.80% patient-level deidentification sensitivity and 99.60% preservation of clinically critical content, performing comparably to proprietary models and outperforming established deidentification tools across most modalities.

Article activity feed