Remote Fingerstick Blood Collection for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Antibody Testing
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
The rapid worldwide spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has propelled the rapid development of serologic tests that can detect anti–SARS-CoV-2 antibodies. These have been used for studying the prevalence and spread of infection in different populations, and helping establish a recent diagnosis of coronavirus disease 2019 (COVID-19), and will likely be used to confirm humoral immunity after infection or vaccination. However, nearly all lab-based high-throughput SARS-CoV-2 serologic assays require a serum sample from venous blood draw, limiting their applications and scalability. Here, we present a method that enables large-scale SARS-CoV-2 serologic studies by combining self or office collection of fingerprick blood with a volumetric absorptive microsampling device (Mitra, Neoteryx LLC) with a high-throughput electrochemiluminescence-based SARS-CoV-2 total antibody assay (Roche Elecsys, Roche Diagnostics Inc) that is emergency use authorization approved for use on serum samples and widely used by clinical laboratories around the world. We found that the Roche Elecsys assay has a high dynamic range that allows for accurate detection of SARS-CoV-2 antibodies in serum samples diluted 1:20 as well as contrived dried blood extracts. Extracts of dried blood from Mitra devices acquired in a community seroprevalence study showed near identical sensitivity and specificity in detection of SARS-CoV-2 antibodies compared with neat sera using predefined thresholds for each specimen type. Overall, this study affirms the use of Mitra dried blood collection device with the Roche Elecsys SARS-CoV-2 total antibody assay for remote or at-home testing as well as large-scale community seroprevalence studies.
Article activity feed
-
-
-
SciScore for 10.1101/2020.10.27.20221028: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Patient samples: Use of patient samples for the development and validation of SARS-CoV-2 diagnostic tests was approved by Partners Institutional Review Board (protocol 2020P000895). Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Antibodies Sentences Resources Roche Elecsys SARS-CoV-2 total antibody assay: We used the electrochemiluminescence-based Roche Elecsys anti-SARS-CoV-2 immunoassay, which detects IgG, IgM, and/or IgA antibodies to the SARS-CoV-2 nucleocapsid protein. anti-SARS-CoV-2 immunoassay, which detects IgGsuggested: NoneIgAsuggested: NoneSARS-CoV-2 nucleocapsid …SciScore for 10.1101/2020.10.27.20221028: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Patient samples: Use of patient samples for the development and validation of SARS-CoV-2 diagnostic tests was approved by Partners Institutional Review Board (protocol 2020P000895). Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Antibodies Sentences Resources Roche Elecsys SARS-CoV-2 total antibody assay: We used the electrochemiluminescence-based Roche Elecsys anti-SARS-CoV-2 immunoassay, which detects IgG, IgM, and/or IgA antibodies to the SARS-CoV-2 nucleocapsid protein. anti-SARS-CoV-2 immunoassay, which detects IgGsuggested: NoneIgAsuggested: NoneSARS-CoV-2 nucleocapsid protein.suggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-