Levels of Produced Antibodies after Vaccination with mRNA Vaccine; Effect of Previous Infection with SARS-CoV-2
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
The aim of this study was to estimate the immunogenic effect of mRNA vaccine against SARS-CoV-2. This study included 510 participants who received mRNA vaccine. The measurement of anti-COVID-19 antibodies was performed using the Abbott SARS-CoV-2 IgG quantitative assay (Abbott). Overall, mean titer of anti-Spike antibodies was 19,319.2 ± 1787.5 AU/mL. Vaccination induced a robust immunogenic response in those previously infected with SARS-CoV-2 compared with non-infected subjects. Additionally, individuals that were asymptomatic after vaccination produced lower levels of antibodies compared to feverish individuals. In conclusion, remarkably high levels of anti-Spike COVID-19 antibodies were observed after vaccination.
Article activity feed
-
-
SciScore for 10.1101/2021.04.05.21254934: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Antibodies Sentences Resources IgG Testing: The measurement of anti-Covid-19 antibodies was performed using the Abbott Architect i1000SR instrument (Abbott Diagnostics, IL, USA) using the Abbott SARS-CoV-2 IgG quantitative kit and following manufacturer’s instructions. anti-Covid-19suggested: NoneSoftware and Algorithms Sentences Resources IgG Testing: The measurement of anti-Covid-19 antibodies was performed using the Abbott Architect i1000SR instrument (Abbott Diagnostics, IL, USA) using the Abbott SARS-CoV-2 IgG … SciScore for 10.1101/2021.04.05.21254934: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Antibodies Sentences Resources IgG Testing: The measurement of anti-Covid-19 antibodies was performed using the Abbott Architect i1000SR instrument (Abbott Diagnostics, IL, USA) using the Abbott SARS-CoV-2 IgG quantitative kit and following manufacturer’s instructions. anti-Covid-19suggested: NoneSoftware and Algorithms Sentences Resources IgG Testing: The measurement of anti-Covid-19 antibodies was performed using the Abbott Architect i1000SR instrument (Abbott Diagnostics, IL, USA) using the Abbott SARS-CoV-2 IgG quantitative kit and following manufacturer’s instructions. Abbott Architectsuggested: (Abbott ARCHITECT i1000sr System, RRID:SCR_019328)Abbottsuggested: (Abbott, RRID:SCR_010477)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:A limitations of the study is the relatively small group of vaccinated patients after SARS CoV infection.
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-
