Efficacy of UVC Radiation in Reducing Bacterial Load on Dental Office Surfaces

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Background/Objectives: Environmental contamination of dental surfaces is a major vector for cross-infection. Ultraviolet-C (UVC) irradiation provides rapid, chemical-free decontamination; however, depending on wavelength and ventilation conditions, ozone generation may occur. This study evaluated the germicidal efficacy of UVC on three high-touch surfaces: a wooden work table, a stainless-steel consumables table, and a dental unit table. Methods: Surfaces were sampled at baseline, after 5 min (27 mJ/cm2), and after 10 min (54 mJ/cm2) of UVC exposure at 90 µW/cm2. Colony-forming units (CFU/cm2) were enumerated using Mueller–Hinton agar. Results: UVC achieved >99% reduction after 5 min and complete elimination after 10 min. Material properties (porosity, reflectivity, and grooves), along with quantified parameters like surface roughness (Ra) and contact angle, influenced minor differences in decontamination. Conclusions: Used with appropriate safety protocols, short-duration UVC irradiation effectively decontaminates dental surfaces and can complement chemical disinfection. Future studies must incorporate artificially soiled surfaces, biofilms, and emerging far-UVC/UV-LED technologies.

Article activity feed