Status of VPU development for PAL-XFEL

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

PAL-XFEL is planning to install second hard X-ray undulator line (HX2) to meet the high beamtime demand from the users. The photon energy range for the second hard X-ray beam line is from 2 to 11 keV which is lower than the first hard X-ray photon energy range (2~ 20 keV). The required undulator parameters are 35 mm period, max K eff =3.48 at 9.00 mm gap, ~3.0 m magnetic length with phase error less than 5 degrees. In addition to the existing conventional undulator design, horizontal gap vertical polarized undulator (HGVPU) concept is also being considered. HGVPU is well developed by the LCLS-II team and applied in the LCLS-II. In this report, we summarize the VPU design for PAL-XFEL HX2, and analyze the results of the prototyping.