Advancing Proton Therapy: Integration of Minibeam Spatial Fractionation and FLASH Dose Rates

Read the full article See related articles

Discuss this preprint

Start a discussion What are Sciety discussions?

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Background Proton minibeam radiation therapy (pMBRT) introduces spatial fractionation of dose distributions at submillimeter resolution, offering a promising approach to reducing normal tissue toxicity while maintaining effective tumor control. However, the high monitor unit (MU) requirements of multi-slit collimators (MSC) result in extended delivery times, posing a significant challenge. This study explores the feasibility of integrating pMBRT with ultra-high-dose-rates (UHDR) to overcome this limitation while leveraging potential biological synergies to enhance the therapeutic index and advance clinical applications. Methods The study utilized the IBA Proteus®ONE compact proton therapy system equipped with two MSCs, each with center-to-center distances of 2.8 mm, slit widths of 1.0 mm, and thicknesses of 6.5 cm and 10 cm. FLASH delivery was achieved with 228 MeV protons at a current of 125 nA, while clinical beams operated at 226 MeV with 1–5 nA. Dose measurements using Gafchromic films in solid water phantoms were compared with Monte Carlo simulations. Delivery times were compared for FLASH and clinical beams. PBS dose rate was calculated based on the spot delivery log file. Results The study successfully demonstrated pMBRT dose distributions under FLASH dose rates, significantly reducing treatment times to 2.5 seconds compared to 3 minutes for clinical beams. The 10 cm collimator achieved higher peak-to-valley dose ratios (PVDRs) at 2 cm depth (4.36) than the 6.5 cm collimator (2.57), optimizing FLASH delivery conditions. Results highlight the potential to improve dose delivery efficiency while maintaining spatial resolution and dose modulation, supporting future clinical advancements. Conclusion This study demonstrates the feasibility of integrating pMBRT with FLASH dose rates using a clinical proton therapy system. By addressing challenges associated with delivery times and leveraging the combined advantages of spatial fractionation and ultra-high-dose-rates, this work paves the way for the clinical translation of pMBRT with FLASH, offering innovative possibilities for treating challenging malignancies with high-dose precision therapy.

Article activity feed