Mechanisms Underlying Superior Clinical Outcomes of Transcatheter Aortic Valve Implantation with the Latest Balloon-Expandable Valve

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Transcatheter aortic valve implantation (TAVI) using SAPIEN 3 Ultra RESILIA (S3UR) offers improved hemodynamic performance than its former generation, SAPIEN 3 (S3). This study compared 1-year clinical outcomes after TAVI using S3UR and S3. Among 2,369 patients from the OCEAN-TAVI registry, a 1:1 propensity score-matched analysis identified 775 matched pairs. One-year post-TAVI, S3UR showed significantly lower all-cause mortality (10.3% vs. 13.4%, p=0.026), stroke (0.9% vs. 3.4%, p=0.001), and heart failure rehospitalization (1.4% vs. 2.7%, p<0.001) than S3. These differences were pronounced in patients receiving smaller valves (20–23 mm). S3UR demonstrated a larger effective orifice area, lower mean pressure gradient, and lower incidence of paravalvular leakage than S3 at discharge. At 1 year, S3UR showed significantly reduced paravalvular leakage and lower incidences of mean pressure gradient ≥20 mmHg than S3. We concluded that S3UR demonstrated superior hemodynamic performance to S3, exhibiting better prognosis, particularly in patients with smaller valves.