Numerical Simulation of Heat Dissipation Characteristics in PWR High-Pressure Coolant Pipes During Cold Shutdown

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Under cold shutdown conditions, heat dissipation performance of the high-pressure coolant pipeline critically impacts pressurized water reactor (PWR) safety by governing residual heat removal efficiency. To quantify key drivers of thermal behavior during stagnant coolant operation, a high-fidelity thermal-hydraulic model is established by using the REALP5 code. Systematic parametric analyses evaluate radiation effects and insulation-environment interactions through three dimensions. The results show that under stagnant coolant and zero-wind conditions, radiation contributes 90% of total heat transfer in the high-pressure coolant pipeline in the vertical direction, yielding a larger coolant temperature drop (ΔT) of 6.12 K over 86400 seconds compared to the no-radiation model. Pipeline heat dissipation exhibits an inverse relationship with insulation cotton thickness but scales positively with material thermal conductivity. Within 800000 seconds, when the insulation cotton thickness(δ) is reduced from 15mm to 5mm, the coolant temperature drops by nearly 18K. This means that for every 10mm reduction in the thickness of insulation cotton(δ), the heat dissipation efficiency increases by 40%. The coolant temperature drop (ΔT) of pipe with asbestos insulation (thermal conductivity λ = 0.046W /(m·K)) reaches 43.98K, which is 53.1% higher than that of the pipe with ultra-fine glass fiber cotton insulation(ΔT = 28.72K) (thermal conductivity λ = 0.022W /(m·K)). Ambient temperature and airflow velocity exhibit inverse and positive correlations with coolant temperature drop (ΔT), the coolant temperature is reduced by 12.51K more than the ambient temperature of 10℃ and 30℃. For every 1℃ decrease in ambient temperature, the temperature drop increases by 0.625K. When the airflow velocity is 0.5m/s compared to 0.1m/s, the coolant temperature drops by 1.65K more. This paper pioneers a high-fidelity thermo-hydraulic model of the main coolant pipeline of PWR under the stagnation condition after cold shutdown, which advances the theoretical framework of heat dissipation such as natural convection in external environment and provides a quantitative safety margin for the removal of waste heat from the core. Further, it guides the design of insulation cotton material and thickness of the high-pressure coolant pipeline and delivers predictive tools for the optimization of heat dissipation strategy after cold shutdown.

Article activity feed