Multi-Reader Evaluation of Deep Learning-Based Auto-Segmentation of Eloquent Brain Arteriovenous Malformation on MRA and White Matter Tractography in Stereotactic Radiosurgery

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Objective: To minimize the radiation injury for white matter (WM) pathways during brain arteriovenous malformation (bAVM) stereotactic radiosurgery (SRS), the WM tractography is integrated into treatment planning to identify WM pathways and restrict receiving dose. Manual segmentation of eloquent bAVM adjacent to WM pathways is time-consuming and prone to substantial inter-practitioner variability due to intricate entanglement within eloquent brain areas. The objective of this study is to develop and evaluate a deep learning (DL) system for the segmentation of eloquent bAVM in a clinical setting. Methods: A total of 191 eloquent bAVM patients who underwent WM tractography and 3D time-of-flight magnetic resonance angiography (TOF-MRA) images were enrolled. 153 patients were used to construct a two-stage DL bAVM segmentation ensemble (TBASE) consisting of 2D detection and 3D segmentation models to segment the bAVM, the other 38 to test performance. Comparative experiments with Res-Net and U-Net were conducted to validate the effectiveness of the proposed network. A randomized multi-reader evaluation was then conducted to assess the impact of TBASE assistance for bAVM segmentation using ten algorithm-unseen cases. Six medical professionals contoured the same series of cases in both assisted and unassisted modes, with a 6-week memory washout period between each session. The aided and unaided Dice Similarity Coefficients (DSC), Hausdorff Distance (HD), along with contouring times were compared. Results: The mean values and standard deviations for DSC and HD of TBASE are 0.87 ± 0.03 and 3.51 ± 0.26, respectively, while Res-Net and U-Net results are 0.75 ± 0.12 and 4.14 ± 0.99, 0.77 ± 0.09 and 3.94 ± 0.82, respectively. The average volume difference across all patients in test dataset is 0.25 ± 1.39 cc, with no statistically significant variation observed. With TBASE assistance, the mean DSC of readers improved from 0.76 ± 0.07 to 0.86 ± 0.05 ( P < 0.001), with corresponding values of mean HD reducing from 4.31 ± 0.68 to 3.35 ± 0.17 ( P < 0.001) and a mean time saving of 52.15% ± 13.85% per patient. Less-experienced readers achieved greater improvements in contouring accuracy compared to specialists (DSC increase: 0.15 ± 0.11 vs 0.06 ± 0.09; P < 0.001), while demonstrating similar reductions in contouring time as specialists (50.68% ± 14.62% vs. 55.1% ± 11.98%; P = 0.217) Conclusions: The reliable eloquent bAVM automated-segmentation method has been validated in clinical workflow. The TBASE assistance improved the accuracy and efficiency of the eloquent bAVM manual delineation and thus avoid neurological sequelae after SRS in considering WM pathways protection.

Article activity feed