Assessment of Body Fat Percentage in Emirati Females: A Comparative Analysis of BIA vs DXA

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Background/Objectives: Obesity is a significant health issue in the UAE. Accurate body composition assessment is crucial for managing obesity-related health risks. This study aimed to evaluate the agreement between Bioelectrical Impedance Analysis (BIA) and Dual-Energy X-ray Absorptiometry (DXA) in measuring body fat percentage (%BF) among Emirati females. Subjects/Methods: This cross-sectional study involved 95 healthy Emirati females aged 17–27 years. Paired samples t-tests, correlation analyses, and Bland-Altman plots were used to compare the two methods. Results BIA significantly underestimated %BF and fat mass (FM) while overestimating fat-free mass (FFM) compared to DXA. The mean difference in %BF was − 14.1% (p < 0.001), and the mean difference in FFM was + 8.2 kg (p < 0.001). Despite strong correlations between BIA and DXA measurements (r = 0.855 for %BF, r = 0.984 for FM, and r = 0.929 for FFM), Bland-Altman plots indicated poor agreement, with wide limits of agreement. Conclusions BIA remains valuable for obesity assessment in large-scale studies and clinical settings due to its non-invasive, easy-to-use, and cost-effective characteristics. The results show that the in-built prediction equations cannot adequately predict the %fat, FM, and FFM for this sample. Future research should focus on developing and validating BIA-specific equations tailored for Emiratis.

Article activity feed