Standardized preservation, extraction and quantification techniques for detection of fecal SARS-CoV-2 RNA
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
COVID-19 patients shed SARS-CoV-2 RNA in stool, sometimes well after their respiratory infection has cleared. In our benchmarking study, we recommend a standardized protocol for the preservation, extraction and detection of viral RNA from stool. This protocol includes a preservative, viral RNA extraction steps, and PCR-based quantification methods to maximize yield and detection of SARS-CoV-2 RNA. Our protocol takes advantage of commercially available reagents and equipment to maximize ease of access and consistency across studies. Additionally, we apply an attenuated bovine coronavirus vaccine as a spike-in control, and synthetic RNA standards to improve standardization and reliability of the assay. While we recommend both ddPCR and RT-qPCR-based assays, we acknowledge that ddPCR may be prohibitively expensive due to the necessity of specialized equipment and reagents. This protocol was developed with a focus on SARS-CoV-2 RNA, but may apply to other coronaviruses as well. We estimate that this protocol takes between 6 to 8 hours total to quantify the viral RNA load in a fecal sample.
Article activity feed
-
-
-
SciScore for 10.1101/2021.04.10.21255250: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources Next, we took two biopsy punches using the Integra Miltex Biopsy Punches with Plunger System (Thermo Fisher Scientific; Catalog # 12-460-410) from each of the relevant stool samples and transferred these to microcentrifuge tubes corresponding to the respective samples. Thermo Fisher Scientific; Catalogsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Res…SciScore for 10.1101/2021.04.10.21255250: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources Next, we took two biopsy punches using the Integra Miltex Biopsy Punches with Plunger System (Thermo Fisher Scientific; Catalog # 12-460-410) from each of the relevant stool samples and transferred these to microcentrifuge tubes corresponding to the respective samples. Thermo Fisher Scientific; Catalogsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-