Comparing Tourniquet Use and Non-Use in Robot-Assisted Total Knee Arthroplasties

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

Background Performance of robot-assisted total knee arthroplasty (TKA) procedures has continued to increase in popularity. However, tourniquet use is necessary for longer periods of time in robot-assisted TKA than conventional manual TKA because the robot-assisted procedure requires an additional registration process. The use of tourniquets for long periods increases the risk of hidden blood loss and ischemic soft tissue injury in the lower extremity. The purpose of this study was to compare the value of performing robot-assisted TKA without the use of a tourniquet to that of performing this surgery with the use of a tourniquet. Parameters we assessed were blood loss, degree of postoperative thigh and knee pain, and occurrence of early post-operative complications. Methods Data from 100 consecutive patients who underwent primary unilateral robot-assisted TKA between July 2024 and July 2025 were included in this study’s analyses. Patients were divided into three groups chronologically. The first 29 patients comprised group 1, the early tourniquet group; the next 30 patients were assigned to group 2, the no tourniquet group; and group 3 was the late tourniquet group and was comprised of the remaining 41 subjects. The primary outcome measure was estimated blood loss (EBL). The secondary outcome measures included transfusion rate, visual analog scale (VAS) pain scores for the knee and thigh on the third postoperative day, readmission rate due to surgical complications, superficial and deep infection rate, length of operation, and length of tourniquet use. Results Group 2 participants, the no tourniquet participants, experienced significantly greater EBL on postoperative days (PODs) 1, 2, and 3 compared to the subjects assigned to groups 1 and 3 (p = 0.003, p < 0.001, and p = 0.005, respectively). However, there were no significant differences in transfusion rates (p = 0.290) among the 3 groups. VAS scores for knee and thigh pain were also not significantly different among the three groups (all p-values > 0.05). Three patients in group 1 (10.3%), one patient in group 2 (3.3%), and one patient in group 3 (2.4%) were readmitted for complications related to wound healing (p = 0.289). Additionally, two patients in group 1 developed superficial wound infections from which the causative bacteria were cultured. No infections were observed in the other groups (p = 0.082), however. Two patients in group 1 and two patients in group 2 experienced symptomatic deep vein thrombosis (DVT) (p = 0.235). No group 3 patients experienced DVT, and only one patient in group 2 was confirmed with DVT using an enhanced CT scan (p = 0.308). Group 3 patients had shorter lengths of surgery (p < 0.001) than group 1 and 2 patients and had shorter periods of tourniquet use (p = 0.034) than group 1 patients. Conclusion Tourniquet non-use in robot-assisted TKA surgeries was associated with greater EBL in acute postoperative periods, but this finding was not accompanied by any change in transfusion rate. Tourniquet non-use was not clinically beneficial for reducing immediate postoperative thigh and knee pain or reducing the prevalence of early post-operative complications. Tourniquet use in robot-assisted TKA is warranted because of the advantages this use provides in maintaining a clear surgical field and in facilitating of the cementing process.

Article activity feed