Particulate Matter Quantification via DINÉ (Digitally INtegrated Environmental) Arduino UNO R3 Platform for Environmental Quality, Safety, and Health

Read the full article See related articles

Listed in

This article is not in any list yet, why not save it to one of your lists.
Log in to save this article

Abstract

After the hardware-integration of an Arduino UNO and the PMSA003 particulate matter (PM) sensor, the Arduino UNO was programmed to count six PM diameters: 0.3, 0.5, 1.0, 2.5, 5, and 10 micrometers, for a fixed air volume of 0.1 Liters. Indoor PM data within 12 different locations at Navajo Preparatory School, Farmington, NM. Outdoor atmospheric PM data was then gathered in Tucson, Arizona, before and after various weather events, such as high winds (PM generating) and rain (PM scrubbing). Additionally, indoor and outdoor data gathered in West Virginia during heavy smoke from the 2023 Canadian forest fires. The output of the Arduino UNO included current, average, maximums, and minimums PM values for each particle size. The Arduino UNO also calculated the least-squares fit a negative-exponential model of the particulate matter as a function of count and particle size, and calculated the correlation “R” between the actual PM count data and the model. Correlations as high as 99.99% were achieved at a confidence of 99.95%. This will help to understand the PM problems on the Navajo Nation, which could include radioactive dust from over 500 abandoned uranium mines.

Article activity feed