Profiling RT-LAMP tolerance of sequence variation for SARS-CoV-2 RNA detection

This article has been Reviewed by the following groups

Read the full article

Abstract

The ongoing SARS-CoV-2 pandemic has necessitated a dramatic increase in our ability to conduct molecular diagnostic tests, as accurate detection of the virus is critical in preventing its spread. However, SARS-CoV-2 variants continue to emerge, with each new variant potentially affecting widely-used nucleic acid amplification diagnostic tests. RT-LAMP has been adopted as a quick, inexpensive diagnostic alternative to RT-qPCR, but as a newer method, has not been studied as thoroughly. Here we interrogate the effect of SARS-CoV-2 sequence mutations on RT-LAMP amplification, creating 523 single point mutation “variants” covering every position of the LAMP primers in 3 SARS-CoV-2 assays and analyzing their effects with over 4,500 RT-LAMP reactions. Remarkably, we observed only minimal effects on amplification speed and no effect on detection sensitivity at positions equivalent to those that significantly impact RT-qPCR assays. We also created primer sets targeting a specific short deletion and observed that LAMP is able to amplify even with a primer containing multiple consecutive mismatched bases, albeit with reduced speed and sensitivity. This highlights RT-LAMP as a robust technique for viral RNA detection that can tolerate most mutations in the primer regions. Additionally, where variant discrimination is desired, we describe the use of molecular beacons to sensitively distinguish and identify variant RNA sequences carrying short deletions. Together these data add to the growing body of knowledge on the utility of RT-LAMP and increase its potential to further our ability to conduct molecular diagnostic tests outside of the traditional clinical laboratory environment.

Article activity feed

  1. SciScore for 10.1101/2021.10.25.465706: (What is this?)

    Please note, not all rigor criteria are appropriate for all manuscripts.

    Table 1: Rigor

    Ethicsnot detected.
    Sex as a biological variablenot detected.
    Randomizationnot detected.
    Blindingnot detected.
    Power Analysisnot detected.

    Table 2: Resources

    Software and Algorithms
    SentencesResources
    Point mutations were identified in GISAID sequences as monitored by NEB Primer Monitor (primer-montor.neb.com), and 4 mutations reported in >10% of deposited sequences from >1 reporting location were chosen for LAMP screening.
    LAMP
    suggested: (LAMP, RRID:SCR_001740)

    Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).


    Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.

    Results from TrialIdentifier: No clinical trial numbers were referenced.


    Results from Barzooka: We did not find any issues relating to the usage of bar graphs.


    Results from JetFighter: We did not find any issues relating to colormaps.


    Results from rtransparent:
    • Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
    • No funding statement was detected.
    • No protocol registration statement was detected.

    Results from scite Reference Check: We found no unreliable references.


    About SciScore

    SciScore is an automated tool that is designed to assist expert reviewers by finding and presenting formulaic information scattered throughout a paper in a standard, easy to digest format. SciScore checks for the presence and correctness of RRIDs (research resource identifiers), and for rigor criteria such as sex and investigator blinding. For details on the theoretical underpinning of rigor criteria and the tools shown here, including references cited, please follow this link.