Seroprevalence of hospital staff in a province with zero COVID-19 cases

This article has been Reviewed by the following groups

Read the full article See related articles

Abstract

COVID-19 seroprevalence data, particularly in less developed countries with a relatively low incidence, has been scant. We aimed to explore the seroprevalence of hospital staff in the area with zero confirmed COVID-19 case to shed light on the situation of COVID-19 infection in zero or low infection rate countries where mass screening was not readily available.

Methods

A locally developed rapid immunoglobulin M (IgM)/immunoglobulin G (IgG) test kit was used for hospital staff screening of Ranong hospital which is located in a province with zero COVID-19 prevalence in Thailand from 17 th April to 17 th May 2020. All staff was tested, 100 of which were randomly invited to have a repeating antibody test in one month. (Thai Clinical Trials Registry: TCTR20200426002)

Results

Of 844 hospital staff, 82 were tested twice one month apart (response rate for repeating antibody test 82%). Overall, 0.8% of the participants (7 of 844) had positive IgM, none had positive IgG. Female staff had 1.0% positive IgM (95% CI: 0.5–2.1%) while male had 0.5% positive IgM (95% CI: 0.1–2.6%). No participants with a history of travel to the high-risk area or close contact with PCR-confirmed COVID-19 case developed SARS-CoV-2 antibodies. Among 844 staff, 811 had no symptoms and six of them developed IgM seropositive (0.7%) while 33 had minor symptoms and only one of them developed IgM seropositive (3.0%). No association between SARS-CoV-2 IgM status and gender, history of travel to a high-risk area, close contact with PCR-confirmed or suspected COVID-19 case, presence of symptoms within 14 days, or previous PCR status was found. None of the hospital staff developed SARS-CoV-2 IgG.

Conclusions

COVID-19 antibody test could detect a considerable number of hospital staff who could be potential silent spreaders in a province with zero COVID-19 cases. Accurate antibody testing is a valuable screening tool, particularly in asymptomatic healthcare workers.

Trial registration: This study was approved by the Institutional Review Board of Chulalongkorn University (IRB No.236/63) and the Institutional Review Board of Ranong Hospital. (Thai Clinical Trials Registry: TCTR20200426002).

Article activity feed

  1. SciScore for 10.1101/2020.07.13.20151944: (What is this?)

    Please note, not all rigor criteria are appropriate for all manuscripts.

    Table 1: Rigor

    Institutional Review Board StatementConsent: All of them accepted to participate with written informed consent.
    IRB: Study approval: This study was approved by the Institutional Review Board of Chulalongkorn University (IRB No.236/63) and the Institutional Review Board of Ranong Hospital. (Thai Clinical Trials Registry: TCTR20200426002)
    RandomizationStudy procedures: On April 17, 2020, of 844 participants, 100 were randomly selected to have their first antibody testing.
    Blindingnot detected.
    Power Analysisnot detected.
    Sex as a biological variablenot detected.

    Table 2: Resources

    Antibodies
    SentencesResources
    The internal validation of the test kit using the serum of 51 PCR confirmed COVID-19 cases and 150 controls showed sensitivity 94.1% (48 of 51) and specificity 98.0% (147 of 150) of IgM or IgG antibody.
    IgG
    suggested: None

    Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).


    Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.

    Results from TrialIdentifier: No clinical trial numbers were referenced.


    Results from Barzooka: We did not find any issues relating to the usage of bar graphs.


    Results from JetFighter: We did not find any issues relating to colormaps.


    Results from rtransparent:
    • Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
    • Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
    • No protocol registration statement was detected.

    About SciScore

    SciScore is an automated tool that is designed to assist expert reviewers by finding and presenting formulaic information scattered throughout a paper in a standard, easy to digest format. SciScore checks for the presence and correctness of RRIDs (research resource identifiers), and for rigor criteria such as sex and investigator blinding. For details on the theoretical underpinning of rigor criteria and the tools shown here, including references cited, please follow this link.