SARS-CoV-2 RNA shedding in recovered COVID-19 cases and the presence of antibodies against SARS-CoV-2 in recovered COVID-19 cases and close contacts, Thailand, April-June 2020
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2020.07.17.208439: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IACUC: The study protocol was approved by the Institutional Ethics Committee (IRB) of the Bangkok Metropolitan Administration, Thailand (IRB No. M001h/63_Exp).
Consent: The IRB waived the need for consent because the used samples were obtained from routine preventive measures and were de-identified and anonymous.Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Antibodies Sentences Resources Detection of antibodies against SARS-CoV-2 by enzyme-linked immunoassays: For recovered COVID-19 cases, IgM, IgG, and IgA antibodies against SARS-CoV-2 were determined, whereas, for close … SciScore for 10.1101/2020.07.17.208439: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IACUC: The study protocol was approved by the Institutional Ethics Committee (IRB) of the Bangkok Metropolitan Administration, Thailand (IRB No. M001h/63_Exp).
Consent: The IRB waived the need for consent because the used samples were obtained from routine preventive measures and were de-identified and anonymous.Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Antibodies Sentences Resources Detection of antibodies against SARS-CoV-2 by enzyme-linked immunoassays: For recovered COVID-19 cases, IgM, IgG, and IgA antibodies against SARS-CoV-2 were determined, whereas, for close contacts, IgG antibodies were investigated in blood samples. IgM, IgGsuggested: NoneSARS-CoV-2suggested: NoneIgGsuggested: NoneThe determination of IgG and IgA antibodies was performed using an ELISA automated system (Euroimmun, Luebeck, Germany) following the manufacturer’s instructions. IgAsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We found bar graphs of continuous data. We recommend replacing bar graphs with more informative graphics, as many different datasets can lead to the same bar graph. The actual data may suggest different conclusions from the summary statistics. For more information, please see Weissgerber et al (2015).
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- No conflict of interest statement was detected. If there are no conflicts, we encourage authors to explicit state so.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-