Serum neopterin levels in relation to mild and severe COVID-19
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Background
The COVID-19 pandemic, caused by the coronavirus SARS-CoV-2, is rapidly spreading worldwide. There is limited information about prognostic markers that could help clinicians to identify COVID-19 patients with a poor prognosis. Serum levels of the immune activation marker neopterin has shown to be of prognostic value in patients with SARS. The aim of this study was to investigate whether serum neopterin is associated with the severity of COVID-19.
Methods
We included 34 patients with confirmed COVID-19 between March 3 and March 30, 2020. Fifteen patients had mild disease and did not require hospitalization, whereas 19 patients developed severe COVID-19 requiring intensive care. Concentrations of serum neopterin, tryptophan, and kynurenine were measured at and repeatedly after inclusion.
Results
We found a more than two-fold higher mean concentration of neopterin in severely ill patients (mean value 42.0 nmol/L (SD 18.2)) compared to patients with mild symptoms (16.9 nmol/L (SD 11.0)). All of the severe cases had elevated neopterin concentrations (> 9.1 nmol/L) at the initial sampling with values ranging from 17.2 to 86.7 nmol/L. In comparison, 10 of 15 patients with mild disease had neopterin levels above 9.1 nmol/L, with concentrations in the range from 4.9 to 31.6 nmol/L. Neopterin levels gradually decreased during the course of COVID-19, but severe cases maintained elevated levels for a longer period. Moreover, lower levels of tryptophan and higher levels of kynurenine, indicating an increased tryptophan catabolism, were seen in the group with severe cases.
Conclusions
In conclusion, we found that serum neopterin levels are associated with the severity of COVID-19. Our findings suggest that neopterin could be used as a prognostic marker, but further studies are needed to elucidate how it can be used in the clinic.
Article activity feed
-
-
SciScore for 10.1101/2020.08.19.20178178: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources Serum TRP and KYN concentrations were measured by a reverse-phase HPLC method (13), using a Varian ProStar HPLC system equipped with a solvent delivery module (model 210), an autosampler (model 400, both Varian ProStar), an UV-spectrometric detector (SPD-6A, Shimadzu), and a fluorescence detector (model 360, Varian ProStar). Variansuggested: NoneAll statistical analyses were performed with the Statistical Package for the Social Sciences (SPSS) software version 25 (SPSS, … SciScore for 10.1101/2020.08.19.20178178: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources Serum TRP and KYN concentrations were measured by a reverse-phase HPLC method (13), using a Varian ProStar HPLC system equipped with a solvent delivery module (model 210), an autosampler (model 400, both Varian ProStar), an UV-spectrometric detector (SPD-6A, Shimadzu), and a fluorescence detector (model 360, Varian ProStar). Variansuggested: NoneAll statistical analyses were performed with the Statistical Package for the Social Sciences (SPSS) software version 25 (SPSS, Chicago, Illinois, USA) or Prism (GraphPad software version 8.0, La Jolla, California, USA). Statistical Package for the Social Sciencessuggested: (SPSS, RRID:SCR_002865)SPSSsuggested: (SPSS, RRID:SCR_002865)Prismsuggested: (PRISM, RRID:SCR_005375)GraphPadsuggested: (GraphPad Prism, RRID:SCR_002798)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:In this context, the lack of creatinine measurements in mild cases make out a limitation of the present study. However, we found no correlation between creatinine and neopterin levels in the severe cases at the first measurement.
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-