Investigating the Sensitivity of Nasal or Throat Swabs: Combination of Both Swabs Increases the Sensitivity of SARS-CoV-2 Rapid Antigen Tests
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
- Evaluated articles (Rapid Reviews Infectious Diseases)
Abstract
This quality project demonstrates that combining the results of nasal and throat swabs or using a combined single swab of the throat and nares resulted in increased detection of SARS-CoV-2 using a rapid antigen test, in an asymptomatic population. Importantly, no false positives were detected, and over 90% of people were willing to perform the combination swab.
Article activity feed
-
-
Gannon C.K. Mak
Review 1: "Investigating Sensitivity of Nasal or Throat (ISNOT): A Combination of Both Swabs Increases Sensitivity of SARS-CoV-2 Rapid Antigen Tests"
-
Strength of evidence
Reviewer: G C.K. Mak (Hong Kong University) | ππππβ»οΈ
-
SciScore for 10.1101/2022.01.18.22269426: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: After providing verbal consent, participants were verbally instructed on, and observed performing, a self-collected bilateral nasal swab, and then guided on self-collection of a posterior oropharyngeal swab, with the aid of an anatomical diagram of the mouth. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Software and Algorithms Sentences Resources Descriptive statistics were used to report participation and testing outcomes, using MedCalc (http://www.medcalc.org) where appropriate. MedCalcsuggested: (MedCalc, RRID:SCR_015044)Results from OddPub: We did not detect open data. We also did not detect β¦
SciScore for 10.1101/2022.01.18.22269426: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: After providing verbal consent, participants were verbally instructed on, and observed performing, a self-collected bilateral nasal swab, and then guided on self-collection of a posterior oropharyngeal swab, with the aid of an anatomical diagram of the mouth. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Software and Algorithms Sentences Resources Descriptive statistics were used to report participation and testing outcomes, using MedCalc (http://www.medcalc.org) where appropriate. MedCalcsuggested: (MedCalc, RRID:SCR_015044)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:This investigation is not without limitations. Our adult population is from a single centre during a seven-day period, at a community testing centre. There was no collection of clinical information related to patient demographics, timing from exposure, immunization history, or recent consumption of food or drink. One of the criteria for attending the testing site was self-described asymptomatic status. However, mild symptoms may not have been recognized as Omicron infection. Practically speaking, swabbing both nasal and throat using a single swab can be done without regard for timing of symptoms or exposure, and should increase rates of detection using Ag-RDTs. This is particularly important as self-directed testing and management become a tool of endemic living, these data add confidence to the ability of individuals to adequately perform reliable sample collection in a real-world setting. Although this project focused on the Abbott Panbio Ag-RDT, the concordant results obtained using the BTNX Rapid Response suggest that this enhanced detection rate using a combined swab is applicable to other lateral flow tests, although further studies are warranted. While molecular confirmation with RT-PCR was available, RTB is not a typical testing matrix. Despite our previous validations of RTB for this application16, this approach is not as sensitive as an independent collection of swabs for RT-PCR testing using dedicated transport media. As such, the sensitivity of Ag-RDTs may be over...
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-