SARS-CoV-2 Triggers an MDA-5-Dependent Interferon Response Which Is Unable To Control Replication in Lung Epithelial Cells

This article has been Reviewed by the following groups

Read the full article See related articles

Abstract

Mammalian cells express sensors able to detect specific features of pathogens and induce the interferon response, which is one of the first lines of defense against viruses and helps in controlling viral replication. The mechanisms and impact of SARS-CoV-2 sensing in lung epithelial cells remain to be deciphered.

Article activity feed

  1. SciScore for 10.1101/2020.10.28.358945: (What is this?)

    Please note, not all rigor criteria are appropriate for all manuscripts.

    Table 1: Rigor

    Institutional Review Board Statementnot detected.
    Randomizationnot detected.
    Blindingnot detected.
    Power Analysisnot detected.
    Sex as a biological variablenot detected.
    Cell Line Authenticationnot detected.

    Table 2: Resources

    Antibodies
    SentencesResources
    An overnight incubation at 4°C with mab J2 (Scicons) followed by incubation in a secondary anti-mouse antibody conjugated to Alexa Fluor 546 and in Alexa Fluor 488 Phalloidin (Thermofisher Scientific) for 2h at RT were used to visualise dsRNA and F-actin, respectively.
    F-actin
    suggested: None
    Cells were incubated on ice for 30-45 min in FACS buffer (PBS1X-5% FCS) containing a 1/250 dilution of Alexa 488-conjugated anti-Spike antibody (GTX632604 conjugated using the Zenon Alexa Fluor 488 Mouse IgG Labeling Kit, ThermoFisher) and washed 4 times in FACS buffer.
    anti-Spike
    suggested: (GeneTex Cat# GTX632604, RRID:AB_2864418)
    , RIG-I (Covalab mab10110), MDA-5 (Ozyme D74E4), and MAVS (ProteinTech 14341-1-AP), followed by secondary horseradish peroxidase-conjugated anti-mouse or anti-rabbit immunoglobulin antibodies and chemiluminescence Clarity or Clarity max substrate (Bio-Rad).
    RIG-I
    suggested: None
    MDA-5
    suggested: (Cell Signaling Technology Cat# 5321, RRID:AB_10694490)
    anti-mouse
    suggested: None
    anti-rabbit immunoglobulin
    suggested: None
    Experimental Models: Cell Lines
    SentencesResources
    Caco-2 and Calu-3 cells were obtained from American Type Culture Collection (ATCC); HEK-Blue™ IFN-α/β and IFN-γ cells were obtained from InvivoGen; 293T, MDCK, A549, Vero E6 cells were gifts from Michael Malim’s lab, Wendy Barclay’s lab, and from the CEMIPAI facility, respectively.
    Caco-2
    suggested: None
    MDCK
    suggested: None
    Vero E6
    suggested: RRID:CVCL_XD71)
    A549 and Caco-2 cells stably expressing ACE2 and TMPRSS2 were generated by transduction with either RRL.sin.cPPT.SFFV/IRES-puro.WPRE, RRL.sin.cPPT.SFFV/IRES-neo.WPRE, RRL.sin.cPPT.SFFV/IRES-hygro.WPRE or RRL.sin.cPPT.SFFV.
    A549
    suggested: NCI-DTP Cat# A549, RRID:CVCL_0023)
    Cas9 activity was checked using the XPR_047 assay (a gift from David Root, Addgene 107145) and was 79.5% and >83.4%, respectively, for Cas9-expressing A549-ACE2 and Calu-3 cells.
    Calu-3
    suggested: KCLB Cat# 30055, RRID:CVCL_0609)
    Lentiviral production and infection: Lentiviral vector stocks were obtained by polyethylenimine (PEI; for LentiGuides) or Lipofectamine 3000 (Thermo Scientific; for ACE2 and TMPRSS2 lentiviral vectors)-mediated multiple transfection of 293T cells in 6-well plates with vectors expressing Gag-Pol, the miniviral genome, the Env glycoprotein at a ratio of 1:1:0.5.
    293T
    suggested: None
    , RIG-I (Covalab mab10110), MDA-5 (Ozyme D74E4), and MAVS (ProteinTech 14341-1-AP), followed by secondary horseradish peroxidase-conjugated anti-mouse or anti-rabbit immunoglobulin antibodies and chemiluminescence Clarity or Clarity max substrate (Bio-Rad).
    MDA-5
    suggested: None
    Software and Algorithms
    SentencesResources
    Post-processing of RAW Airyscan images was performed using the Zen Black software.
    Zen Black
    suggested: (Black Zen software, RRID:SCR_018163)

    Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).


    Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.

    Results from TrialIdentifier: No clinical trial numbers were referenced.


    Results from Barzooka: We did not find any issues relating to the usage of bar graphs.


    Results from JetFighter: We did not find any issues relating to colormaps.


    Results from rtransparent:
    • Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
    • Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
    • No protocol registration statement was detected.

    About SciScore

    SciScore is an automated tool that is designed to assist expert reviewers by finding and presenting formulaic information scattered throughout a paper in a standard, easy to digest format. SciScore checks for the presence and correctness of RRIDs (research resource identifiers), and for rigor criteria such as sex and investigator blinding. For details on the theoretical underpinning of rigor criteria and the tools shown here, including references cited, please follow this link.