Abstract

Purpose

Cardiotoxicity is a major concern for patients undergoing thoracic radiotherapy. This study compared the predictive power of radiation dose-volume histogram (DVH) parameters and radiomic/dosiomic features of the whole heart (WH) and cardiac substructures for elevated circulating high-sensitivity cardiac troponin T (hs-cTnT), a biomarker for early detection of cardiac adverse events.

Methods and Materials

A retrospective cohort of 160 patients with non-small cell lung cancer (NSCLC) from a completed prospective trial and a prospective cohort of 57 patients with NSCLC enrolled in an ongoing trial were analyzed. The endpoint was hs-cTnT elevation, indicated by increase of ≥5 ng/L from baseline. An in-house auto-segmentation model delineated 19 cardiac substructures. DVH parameters, radiomic, and dosiomic features were extracted from each patient. A 100-iteration Monte Carlo cross-validation (75%/25% split) was conducted within the retrospective cohort to mitigate random split bias. Logistic regression models using different input combinations were compared, with a model using only clinical factors served as the baseline. Key predictive features were identified using permutation importance during training. Models were validated by hold-out in the prospective cohort to evaluate robustness.

Model performance was assessed by area under the receiver operating characteristic curve (AUROC).

Results

Incidence of hs-cTnT elevation was 31.9% in the retrospective and 29.8% in the prospective cohort. The substructure DVH model achieved the highest predictive performance in cross-validation (mean AUROC 0.71, 95% CI [0.70, 0.73]) and demonstrated greater robustness in hold-out validation compared to WH-based models (AUROC 0.60 vs. ≤0.51). Feature analysis identified the left anterior descending coronary artery V20Gy as the most dominant predictor, with cut-off values ranging from 0.2%-5% using various indices.

Conclusions

Cardiac substructure DVH parameters have superior predictive power and robustness over WH variables for predicting hs-cTnT elevation in NSCLC radiotherapy, emphasizing the need of using cardiac substructures for cardiotoxicity risk assessment.