Detection Of SARS-COV-2 Variants Of Concern In Wastewater Of Leuven, Belgium
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
To investigate whether wastewater surveillance can be used as an early warning system to detect a rise in SARS-CoV-2 positive cases, and to follow the circulation of specific variants of concern (VOC) in particular geographical areas, wastewater samples were collected from local neighborhood sewers and from a large regional wastewater treatment plant (WWTP) in the area of Leuven, Belgium. In two residential sampling sites, a rise in viral SARS-CoV-2 copies in wastewater preceded the peaks in positive cases. In the WWTP, peaks in the wastewater viral load were seen simultaneous with the waves op positive cases caused by the original Wuhan SARS-CoV-2 strain, the Alpha variant and the Delta variant. For the Omicron BA.1 variant associated wave, the viral load in wastewater increased to a lesser degree, and much later than the increase in positive cases, which could be attributed to a lower level of fecal excretion, as measured in hospitalized patients. Circulation of SARS-CoV-2 VOCs (Alpha, Delta and Omicron) could be detected based on the presence of specific key mutations. The shift in variants was noticeable in the wastewater, with key mutations of two different variants being present simultaneously during the transition period.
We found that wastewater based surveillance is a sensitive tool to monitor SARS-CoV-2 circulation levels and VOCs in larger regions. This can prove to be highly valuable in times of reducing testing capacity. Differences in excretion levels of various SARS-CoV-2 variants should however be taken into account when using wastewater surveillance to monitor SARS-CoV-2 circulation levels in the population.
Article activity feed
-
SciScore for 10.1101/2022.05.12.22274823: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics IRB: The use of patients residual materials by the National Reference Center for coronaviruses for SARS-CoV-2 research was approved by the UZ Leuven Ethics Committee. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier:…
SciScore for 10.1101/2022.05.12.22274823: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics IRB: The use of patients residual materials by the National Reference Center for coronaviruses for SARS-CoV-2 research was approved by the UZ Leuven Ethics Committee. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-