Quantifying the Relationship between SARS-CoV-2 Wastewater Concentrations and Building-Level COVID-19 Prevalence at an Isolation Residence: A Passive Sampling Approach
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
SARS-CoV-2 RNA loads can be detected in the excreta of individuals with COVID-19 and have demonstrated positive correlations with clinical infection trends. Consequently, wastewater-based epidemiology (WBE) approaches have been implemented globally as a public health surveillance tool to monitor community-level prevalence of infections. The majority of wastewater specimens are gathered as either composite samples via automatic samplers (autosamplers) or grab samples. However, autosamplers are expensive and can be challenging to maintain in cold weather, while grab samples are particularly susceptible to temporal variation when sampling sewage directly from complex matrices outside residential buildings. Passive sampling can provide an affordable, practical, and scalable sampling system while maintaining a reproducible SARS-CoV-2 signal. In this regard, we deployed tampons as passive samplers outside of a COVID-19 isolation unit (a segregated residence hall) at a university campus from 1 February 2021–21 May 2021. Samples (n = 64) were collected 3–5 times weekly and remained within the sewer for a median duration of 24 h. SARS-CoV-2 RNA was quantified using reverse-transcription quantitative polymerase chain reaction (RT-qPCR) targeting the N1 and N2 gene fragments. We quantified the mean viral load captured per individual and the association between the daily viral load and total persons, adjusting for covariates using multivariable models to provide a baseline estimate of viral shedding. Samples were processed through two distinct laboratory pipelines on campus, yielding highly correlated N2 concentrations. Data obtained here highlight the success of passive sampling utilizing tampons to capture SARS-CoV-2 in wastewater coming from a COVID-19 isolation residence, indicating that this method can help inform building-level public health responses.
Article activity feed
-
-
SciScore for 10.1101/2022.04.07.22273534: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics IRB: The public health surveillance program was approved by the Institutional Review Board (#20-258); this research protocol had a separate filing (approval #21-140). Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Recombinant DNA Sentences Resources Standard curves for the N1 and N2 analyses were generated by quantifying a synthesized SARS-CoV-2 plasmid manufactured by IDT (Cat No. 10006625). SARS-CoV-2suggested: RRID:Addgene_164583)Software and Algorithms Sentences Resources 2.6 Data analysis: Statistical analyses were performed using SAS 9.4 (SAS Institute, Cary, NC, USA), and visualizations were created using … SciScore for 10.1101/2022.04.07.22273534: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics IRB: The public health surveillance program was approved by the Institutional Review Board (#20-258); this research protocol had a separate filing (approval #21-140). Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Recombinant DNA Sentences Resources Standard curves for the N1 and N2 analyses were generated by quantifying a synthesized SARS-CoV-2 plasmid manufactured by IDT (Cat No. 10006625). SARS-CoV-2suggested: RRID:Addgene_164583)Software and Algorithms Sentences Resources 2.6 Data analysis: Statistical analyses were performed using SAS 9.4 (SAS Institute, Cary, NC, USA), and visualizations were created using RStudio (ver. 1.4.1103) with ggplot2 (ver. 3.3.5). SAS Institutesuggested: (Statistical Analysis System, RRID:SCR_008567)RStudiosuggested: (RStudio, RRID:SCR_000432)ggplot2suggested: (ggplot2, RRID:SCR_014601)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:3.5 Limitations: Several characteristics relating to this research need to be further explored, and various limitations should be considered in generalizing the findings outlined above. First, most passive samples (nearly 90%) remained in the sewer for 24 hours; however, some were left at the isolation residence for more than one day. A sensitivity analysis excluding these samples left in the sewer for an extended period shows a 44% increase in the occupancy count for each one unit increase in the log-transformed wastewater SARS-CoV-2 daily load, adjusting for BRSV recovery and the percentage of females in the building (IRR 1.44, 95% CI 1.22-1.70). Though only students with a positive COVID-19 clinical test resided in the isolation building, we cannot exclude the possibility of staff members contributing to the building-level water use, which could bias results. Also, it is necessary to note that the quantification of SARS-CoV-2 gene copies/L of wastewater, as measured using the raw influent sewage captured by our passive samplers, may not precisely represent the actual composition of sewage throughout the 24-hour sampling period. Instead, our quantification of SARS-CoV-2 gene copies in the wastewater comes from the “extracted” wastewater over the 24-hour time span, which was required to normalize the N1 and N2 signals to daily flow conveniently. Moreover, hourly flow data and bathroom-level flush counts may have provided more information on day-to-day student behavior. All s...
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-