Detection of COVID-19 and age-dependent dysosmia with paired crushable odorant ampules

This article has been Reviewed by the following groups

Read the full article

Abstract

Background

Signs of anosmia can help detect COVID-19 infection when testing for viral positivity is not available. Inexpensive mass-produced disposable olfactory sensitivity tests suitable for worldwide use might serve not only as a screening tool for potential infection but also to identify cases at elevated risk of severe disease as anosmic COVID-19 patients have a better prognosis.

Methods and Findings

We adopted paired crushable ampules with two concentrations of a standard test odorant (n-butanol) as standard of care in several clinics as community prevalence of COVID-19 infection waxed and waned. This was not a clinical trial; a chart review was undertaken to evaluate the operating characteristics and potential utility of the test device as RT-PCR testing became routine. The risk of anosmia was greater in COVID-19 patients. Olfactory sensitivity was concentration-dependent, decreased with aging, and was sex-dependent at the highest concentration. Hyposmia was detected across a wider age range than expected from the literature, and tests can be optimized to characterize different age groups.

Conclusions

n-Butanol at 0.32 and 3.2% in crushable ampules can be used to characterize olfactory function quickly and inexpensively and thus has potential benefits in pandemic screening, epidemiology, and clinical decision-making.

Article activity feed

  1. SciScore for 10.1101/2022.03.13.22271253: (What is this?)

    Please note, not all rigor criteria are appropriate for all manuscripts.

    Table 1: Rigor

    Ethicsnot detected.
    Sex as a biological variablenot detected.
    Randomizationnot detected.
    Blindingnot detected.
    Power Analysisnot detected.

    Table 2: Resources

    No key resources detected.


    Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).


    Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.

    Results from TrialIdentifier: No clinical trial numbers were referenced.


    Results from Barzooka: We did not find any issues relating to the usage of bar graphs.


    Results from JetFighter: We did not find any issues relating to colormaps.


    Results from rtransparent:
    • Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
    • Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
    • No protocol registration statement was detected.

    Results from scite Reference Check: We found no unreliable references.


    About SciScore

    SciScore is an automated tool that is designed to assist expert reviewers by finding and presenting formulaic information scattered throughout a paper in a standard, easy to digest format. SciScore checks for the presence and correctness of RRIDs (research resource identifiers), and for rigor criteria such as sex and investigator blinding. For details on the theoretical underpinning of rigor criteria and the tools shown here, including references cited, please follow this link.