Unexplained longitudinal variability in COVID-19 antibody status by Lateral Flow Immuno-Antibody testing
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
COVID-19 antibody testing allows population studies to classify participants by previous SARS-CoV-2 infection status. Home lateral flow immune-antibody testing devices offer a very convenient way of doing this, but relatively little is known about how measurement and antibody variability will affect consistency in results over time. We examined consistency by looking at the outcome of two tests three months apart while COVID-19 infection rates were low (summer 2020 in the UK).
Methods
The KCL-Coronavirus Health and Experiences in Colleagues at King’s is an occupational cohort of staff and postgraduate research students. Lateral flow immune-antibody testing kits were sent to participant’s homes in late June 2020 and late September 2020. Participants also completed regular surveys that included asking about COVID-19 symptoms and whether they thought they had been infected.
Results
We studied 1489 participants returned valid results in both June and September (59% of those sent kits). Lateral flow immune-antibody test was positive for 7.2% in June and 5.9% in September, with 3.9% positive in both. Being more symptomatic or suspecting infection increased the probability of ever being positive. Of those positive in June, 46% (49/107) were negative in September (seroreversion), and this was similar regardless of symptom characteristics, suspicion, and timing of possible infection. A possible outlier was those aged over 55 years, where only 3 of 13 (23%) had seroreversion.
Discussion
These results do not follow the pattern reported from studies specifically designed to monitor seropositivity, which have found greater consistency over time and the influence of presence, timing and severity of symptoms on seroreversion. We suggest several factors that may have contributed to this difference: our low bar in defining initial seropositivity (single test); a non-quantitative test known to have relatively low sensitivity; participants carrying out testing. We would encourage other studies to use these real-world performance characteristics alongside those from laboratory studies to plan and analyse any antibody testing.
Article activity feed
-
SciScore for 10.1101/2021.08.23.21261638: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable Our previous paper compared the cohort with antibody results to the known characteristics of staff and PGRs, showing that women and people with White ethnicity were over-represented. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from …
SciScore for 10.1101/2021.08.23.21261638: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable Our previous paper compared the cohort with antibody results to the known characteristics of staff and PGRs, showing that women and people with White ethnicity were over-represented. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-