SARS-CoV-2 variants of concern, Gamma (P.1) and Delta (B.1.617), sensitive detection and quantification in wastewater employing direct RT-qPCR
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
SARS-CoV-2 variants of concern present a worldwide threat. Demonstrating higher infection rate and durability to antibodies when compared to the original SARS-CoV-2 virus, the variants of concern are responsible for continuing global outbreaks. Prompt identification of the infecting SARS-CoV-2 variant is essential for pandemic assessment and containment. However, variant identification is mainly being performed using expensive, time-consuming next generation sequencing. Rapid identification methodology for variants of concern is of great need and various variant-specific assays are being developed. Amongst the variants of concern that have recently appeared, the Gamma variant (P.1, Brazilian) and Delta variant (B.1.617, Indian) are the most prominent. Here we describe the development of a sensitive RT-qPCR assay for the quick direct detection of the Gamma and Delta variants as part of a methodical characterization and detection in municipal wastewater.
Article activity feed
-
SciScore for 10.1101/2021.07.14.21260495: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Software and Algorithms Sentences Resources Primers and probes design: The original sequence of SARS-CoV-2 (NC_045512.2) was taken from NCBI database. NCBIsuggested: (NCBI, RRID:SCR_006472)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdent…
SciScore for 10.1101/2021.07.14.21260495: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Software and Algorithms Sentences Resources Primers and probes design: The original sequence of SARS-CoV-2 (NC_045512.2) was taken from NCBI database. NCBIsuggested: (NCBI, RRID:SCR_006472)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-